Literature DB >> 1246142

Evaluation of aortic valve replacement with a porcine xenograft without long-term anticoagulation.

R D Pipkin, W S Buch, T J Fogarty.   

Abstract

From June, 1971, through November, 1974, 75 patients underwent aortic valve replacement with a Hancock "Stabilized Glutaraldehyde Process" porcine xenograft. Patients who underwent multiple valve replacements are not included in the study. Thirty-nine per cent of the patients had procedures for associated lesions or for removal of a Starr-Edwards prosthesis. The operative mortality rate was 6.7 per cent. Six patients died in the late postoperative period. Only one death was thought to be secondary to a valve-related problem. Actuarial analysis predicts 84 per cent survival at 3 years. Three patients initially received long-term antithromboembolic therapy. There have been three suspected or documented thromboembolic episodes (0.24 per cent per patient-month). Ten per cent of the patients surviving the operation developed murmurs of aortic insufficiency. There have been no documented valve failures. Ninety-eight per cent of the survivors have experienced an improvement in their New York Heart Association (N.Y.H.A.) classification.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1246142

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  6 in total

1.  Glutaraldehyde inactivation of exotic animal viruses in swine heart tissue.

Authors:  H R Cunliffe; J H Blackwell; J S Walker
Journal:  Appl Environ Microbiol       Date:  1979-05       Impact factor: 4.792

2.  Surgical considerations in aortic valve disease.

Authors:  P O Daily
Journal:  West J Med       Date:  1977-06

3.  Early clinical experience with the Hancock porcine xenograft valve prosthesis.

Authors:  C T Sang; J Wallwork; H C Miller; A H Kitchin; K G Davidson; P K Caves
Journal:  Br Heart J       Date:  1979-02

4.  Calcification of glutaraldehyde-fixed porcine xenograft.

Authors:  A G Rose; R Forman; R M Bowen
Journal:  Thorax       Date:  1978-02       Impact factor: 9.139

Review 5.  Bioengineering aspects of heart valve replacement.

Authors:  F J Schoen; J L Titus; G M Lawrie
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

6.  Ionescu-Shiley pericardial xenograft valve: Hemodynamic evaluation and early clinical follow-up of 326 patients.

Authors:  David A. Ott; Aldemire T. Coelho; Denton A. Cooley; George J. Reul
Journal:  Cardiovasc Dis       Date:  1980-06
  6 in total