Literature DB >> 12461268

Hemodialysis access imaging: comparison of flow-interrupted contrast-enhanced MR angiography and digital subtraction angiography.

Johannes H M Smits1, Clemens Bos, Otto E H Elgersma, Wil A M A van der Mark, Peter J Blankestijn, Chris J G Bakker, Jan J Zijlstra, Sandra Kalmijn, Willem P T M Mali.   

Abstract

PURPOSE: To compare flow-interrupted contrast material-enhanced magnetic resonance (MR) angiography with conventional digital subtraction angiography (DSA) for hemodialysis access imaging.
MATERIALS AND METHODS: Twenty-two accesses (14 arteriovenous grafts [AVGs], eight arteriovenous fistulas [AVFs]) in 18 consecutive patients were imaged with flow-interrupted contrast-enhanced MR angiography and subsequent conventional DSA. MR image quality was assessed as excellent, good, or nondiagnostic. Anastomotic diameters in AVGs and postanastomotic diameters in AVFs were measured in consideration of an adjacent normal segment. Reductions in the diameter of the lumen and interobserver differences were analyzed with method comparison as described by Bland and Altman and expressed as the mean difference with its 95% confidence limits (CLs) (mean +/- 2 SDs).
RESULTS: Image quality obtained with flow-interrupted contrast-enhanced MR angiography was considered excellent in 73% (16 of 22) and good in 23% (5 of 22). Method comparison analysis between MR angiography and DSA indicated a mean difference of 3.2% (95% CLs: -26.7%, 33.1%) for observer 1 and 4.1% (95% CLs: -23.8%, 32.1%) for observer 2. Interobserver analysis at MR angiography indicated a mean difference of 3.2% (95% CLs: -28.8%, 35.2%), and that at DSA indicated a mean difference of 3.6% (95% CLs: -9.4%, 16.7%).
CONCLUSION: Image quality and anatomic depiction with flow-interrupted contrast-enhanced MR angiography and with DSA were comparable. Copyright RSNA, 2002

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12461268     DOI: 10.1148/radiol.2253010879

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  2 in total

1.  Embolic occlusion of arteriovenous fistula due to infective endocarditis.

Authors:  R Ram; G Swarnalatha; S Mahapatra; K V Dakshinamurty
Journal:  Indian J Nephrol       Date:  2014-11

2.  Longitudinal assessment of hyperplasia using magnetic resonance imaging without contrast in a porcine arteriovenous graft model.

Authors:  Christi M Terry; Seong-Eun Kim; Li Li; K Craig Goodrich; J Rock Hadley; Donald K Blumenthal; Dennis L Parker; Alfred K Cheung
Journal:  Acad Radiol       Date:  2009-01       Impact factor: 3.173

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.