Transcranial duplex sonography in the detection of patent foramen ovale.

Wendelin K Blersch1, Bogdan M Draganski, Stefan R Holmer, Horst J Koch, Felix Schlachetzki, Ullrich Bogdahn, Thilo Hölscher.   

Abstract

PURPOSE: To determine the sensitivity of contrast material-enhanced transcranial color-coded sonography (c-TCCS) compared with that of contrast-enhanced transesophageal echocardiography (c-TEE) for detection of cardiac right-to-left shunt.
MATERIALS AND METHODS: Forty consecutive patients with stroke or transient ischemic attack were admitted to the hospital and were examined by using c-TCCS and c-TEE. High-intensity transient signals (HITS) were counted for 25 seconds after the end of the Valsalva maneuver, and the numbers of HITS were classified in one of four categories (zero HITS, one to 10 HITS, >10 HITS without curtain, and curtain). A statistically significant difference was calculated with the Fisher exact test.
RESULTS: HITS were counted in 21 (52%) patients by using c-TCCS and c-TEE. With both tests, no HITS were counted in 15 (38%) patients. In two (5%) patients, no HITS were counted with c-TEE but three HITS in one patient and five HITS in the other were counted with c-TCCS. In two (5%) patients, no HITS were counted with c-TCCS, but a small patent foramen ovale (PFO) was seen at c-TEE. With c-TCCS, the sensitivity was 91% (21 of 23) and the specificity was 88% (15 of 17). In 23 patients examined with c-TCCS, 14 (61%) patients had category 1 PFO; seven (30%) patients, category 2 PFO; and two (9%) patients, category 3 PFO. Mean HITS count in patients with category 1 PFO was 4.4 and that for those with category 2 PFO was 27.6.
CONCLUSION: c-TCCS is a sensitive noninvasive method for detecting cardiac right-to-left shunt and is as sensitive as c-TEE.

Entities:  

Mesh:

Year:  2002        PMID: 12461247     DOI: 10.1148/radiol.2253011572

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

Review 1.  When and how to diagnose patent foramen ovale.

Authors:  F J Pinto
Journal:  Heart       Date:  2005-04       Impact factor: 5.994

Review 2.  Patent foramen ovale and atrial septal aneurysm in cryptogenic stroke.

Authors:  Sujoy Ghosh; Arjun Kumar Ghosh; Sandip Kumar Ghosh
Journal:  Postgrad Med J       Date:  2007-03       Impact factor: 2.401

3.  Paradoxical brain embolism caused by an arterial-venous fistula: a diagnostic pitfall.

Authors:  Piergiorgio Lochner; Frediano Tezzon; Rafaelle Nardone; Christian Tanislav
Journal:  Neurol Sci       Date:  2009-11-21       Impact factor: 3.307

4.  Sensitivity of transcranial Doppler versus intracardiac echocardiography in the detection of right-to-left shunt.

Authors:  HoHai Van; Paul Poommipanit; Mostafa Shalaby; Rubine Gevorgyan; Chi-Hong Tseng; Jonathan Tobis
Journal:  JACC Cardiovasc Imaging       Date:  2010-04

5.  Prevalence of patent foramen ovale in ischemic stroke in Italy: the SISIFO study.

Authors:  Domenico Consoli; Maurizio Paciaroni; Marco Aguggia; Maurizio Melis; Giovanni Malferrari; Simone Vidale; Paolo Cerrato; Simona Sacco; Carlo Gandolfo; Paolo Bovi; Carlo Serrati; Massimo Del Sette; Anna Cavallini; Marina Diomedi; Paolo Postorino; Stefano Ricci
Journal:  Neurol Sci       Date:  2014-01-01       Impact factor: 3.307

6.  Serpentine thrombus in the heart: a rare case of trapped thrombus in patent foramen ovale.

Authors:  Dominika M Zoltowska; Yashwant Agrawal; Jagadeesh K Kalavakunta
Journal:  BMJ Case Rep       Date:  2018-03-21

Review 7.  Intracardiac shunting and stroke in children: a systematic review.

Authors:  Michael M Dowling; Catherine M Ikemba
Journal:  J Child Neurol       Date:  2011-01       Impact factor: 1.987

8.  Sleep Apnea in Patients with and without a Right-to-Left Shunt.

Authors:  Mohammad Khalid Mojadidi; Pooya Isaac Bokhoor; Rubine Gevorgyan; Nabil Noureddin; W Cameron MacLellan; Eugenia Wen; Ravi Aysola; Jonathan M Tobis
Journal:  J Clin Sleep Med       Date:  2015-11-15       Impact factor: 4.062

9.  Patent foramen ovale detected by near-infrared spectroscopy in patients suffering from migraine with aura.

Authors:  William Liboni; Filippo Molinari; Giovanni Battista Allais; Ornella Mana; Emanuela Negri; Giovanni D'Andrea; Gennaro Bussone; Chiara Benedetto
Journal:  Neurol Sci       Date:  2008-05       Impact factor: 3.307

10.  The incidence of peripheral arterial embolism in association with a patent foramen ovale (right-to-left shunt).

Authors:  Yusuf Ali Kausar Rushdi; Hina Hina; Bijendra Patel; Frank W Cross
Journal:  JRSM Short Rep       Date:  2011-05-03