A comparison of phantoms for cross-calibration of lumbar spine DXA.

D Pearson1, S A Cawte, D J Green.   

Abstract

The aim of this project was to compare three phantoms used for cross-calibration of dual-energy X-ray absorptiometers with an in vivo cross-calibration. The phantoms used were the Bona Fide Phantom (BFP), the European Spine Phantom (ESP) and the GE Lunar Aluminum Spine Phantom (ASP). The cross calibration was for L2-L4 lumbar spine bone mineral density (BMD) on a GE Lunar DPX-L and Hologic QDR 2000. The in vivo cross-calibration was obtained using 72 subjects (61 female, 11 male; mean age 49 years, range 14-84 years). The phantoms were measured 10 times without repositioning on both instruments. A further, long-term cross-calibration was obtained with the BFP over a 9 month period. The true linear relationship between the two instruments was calculated used a standardized principal components method. The mean residuals were calculated between each phantom cross-calibration line and the in vivo data to obtain a measure of the goodness of fit between the phantom cross-calibration and the in vivo data. There was no significant difference between the in vitro and in vivo cross-calibrations. The long-term BFP cross-calibration gave an in vitro cross-calibration that is closest to the in vivo cross-calibration in this group of subjects. When calculating Hologic QDR BMD from results on the GE Lunar DPX-L, the ASP underestimates Hologic QDR 2000 BMD by 4% at high BMD and overestimates by 4% at low BMD. The ESP cross-calibration overestimates Hologic QDR2000 BMD by 1% at high BMD and 4% at low BMD. The BFP performs best, overestimating Hologic QDR2000 BMD by between 1.2% and 1.8%, whilst the difference between the long-term BFP cross-calibration and the in vivo data is less than 1% over the range of BMD covered.

Entities:  

Mesh:

Year:  2002        PMID: 12459937     DOI: 10.1007/s001980200132

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  6 in total

1.  Pediatric in vivo cross-calibration between the GE Lunar Prodigy and DPX-L bone densitometers.

Authors:  Nicola J Crabtree; N J Shaw; C M Boivin; B Oldroyd; J G Truscott
Journal:  Osteoporos Int       Date:  2005-10-19       Impact factor: 4.507

2.  A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

Authors:  Diane Krueger; Jessie Libber; Jennifer Sanfilippo; Hui Jing Yu; Blaine Horvath; Colin G Miller; Neil Binkley
Journal:  J Clin Densitom       Date:  2015-06-10       Impact factor: 2.617

3.  Fragility fractures and bone mineral density in HIV positive women: a case-control population-based study.

Authors:  J Prior; D Burdge; E Maan; R Milner; C Hankins; M Klein; S Walmsley
Journal:  Osteoporos Int       Date:  2007-07-31       Impact factor: 4.507

4.  Bone mineral density determinations by dual-energy x-ray absorptiometry in the management of patients with Marfan syndrome--some factors which affect the measurement.

Authors:  Philip F Giampietro; Margaret G E Peterson; Robert Schneider; Jessica G Davis; Stephen W Burke; Oheneba Boachie-Adjei; Charles M Mueller; Cathleen L Raggio
Journal:  HSS J       Date:  2007-02

5.  Cross-Calibration of GE Healthcare Lunar Prodigy and iDXA Dual-Energy X-Ray Densitometers for Bone Mineral Measurements.

Authors:  J Saarelainen; M Hakulinen; T Rikkonen; H Kröger; M Tuppurainen; H Koivumaa-Honkanen; R Honkanen; M Hujo; J S Jurvelin
Journal:  J Osteoporos       Date:  2016-04-27

6.  Characteristics of Long-Term Femoral Neck Bone Loss in Postmenopausal Women: A 25-Year Follow-Up.

Authors:  Anna Moilanen; Juho Kopra; Heikki Kröger; Reijo Sund; Toni Rikkonen; Joonas Sirola
Journal:  J Bone Miner Res       Date:  2021-10-19       Impact factor: 6.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.