Literature DB >> 12457257

Estimates of interventricular septum thickness are markedly affected by the method used.

T Poutanen1, T Tikanoja.   

Abstract

Modern echocardiographic techniques allow precise measurements of interventricular septum thickness by two-dimensional echocardiography (2DE) and M-mode echocardiography. The advantage of 2DE is the more accurate estimate in cases in which the shape of the septum differs from normal. However, the usefulness of measurements by 2DE is limited due to the lack of reference values. We measured maximal septum thickness by 2DE in 168 healthy subjects aged 2 to 27 years and compared the results to those obtained by M-mode. In agreement analysis the bias +/- 2 SD between 2DE and M-mode was 0.8 +/- 1.7 mm (p <0.001). Maximal septum thickness exceeded the upper normal limit (+2 SD) of the largest pediatric reference data in 14 (8%) of the healthy subjects studied. Interventricular septum thickness is greater when measured by 2DE than by M-mode. Previous M-mode reference values should be used with caution; preferably, reference data based on 2DE should be used.

Entities:  

Mesh:

Year:  2002        PMID: 12457257     DOI: 10.1007/s00246-002-0296-z

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  12 in total

1.  Echocardiographic pitfalls in the diagnosis of hypertrophic cardiomyopathy.

Authors:  K Prasad; J Atherton; G C Smith; W J McKenna; M P Frenneaux; P Nihoyannopoulos
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

2.  A formula to estimate the approximate surface area if height and weight be known. 1916.

Authors:  D Du Bois; E F Du Bois
Journal:  Nutrition       Date:  1989 Sep-Oct       Impact factor: 4.008

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.

Authors:  D J Sahn; A DeMaria; J Kisslo; A Weyman
Journal:  Circulation       Date:  1978-12       Impact factor: 29.690

5.  Echocardiographic measurements in normal subjects from infancy to old age.

Authors:  W L Henry; J M Gardin; J H Ware
Journal:  Circulation       Date:  1980-11       Impact factor: 29.690

6.  Normal values of M mode echocardiographic measurements of more than 2000 healthy infants and children in central Europe.

Authors:  C Kampmann; C M Wiethoff; A Wenzel; G Stolz; M Betancor; C F Wippermann; R G Huth; P Habermehl; M Knuf; T Emschermann; H Stopfkuchen
Journal:  Heart       Date:  2000-06       Impact factor: 5.994

7.  Diagnostic value of electrocardiography and echocardiography for familial hypertrophic cardiomyopathy in genotyped children.

Authors:  P Charron; O Dubourg; M Desnos; J B Bouhour; R Isnard; A Hagege; L Carrier; G Bonne; F Tesson; P Richard; B Hainque; K Schwartz; M Komajda
Journal:  Eur Heart J       Date:  1998-09       Impact factor: 29.983

8.  Age and body surface area related normal upper and lower limits of M mode echocardiographic measurements and left ventricular volume and mass from infancy to early adulthood.

Authors:  F U Huwez; A B Houston; J Watson; S McLaughlin; P W Macfarlane
Journal:  Br Heart J       Date:  1994-09

9.  Relation between extent of left ventricular hypertrophy and age in hypertrophic cardiomyopathy.

Authors:  P Spirito; B J Maron
Journal:  J Am Coll Cardiol       Date:  1989-03-15       Impact factor: 24.094

10.  Development and progression of left ventricular hypertrophy in children with hypertrophic cardiomyopathy.

Authors:  B J Maron; P Spirito; Y Wesley; J Arce
Journal:  N Engl J Med       Date:  1986-09-04       Impact factor: 91.245

View more