Literature DB >> 12455743

Monitoring pulmonary function with superimposed pulmonary gas exchange curves from standard analyzers.

Harvey A Zar1, Frances E Noe, James E Szalados, Michael D Goodrich, Michael G Busby.   

Abstract

OBJECTIVE: A repetitive graphic display of the single breath pulmonary function can indicate changes in cardiac and pulmonary physiology brought on by clinical events. Parallel advances in computer technology and monitoring make real-time, single breath pulmonary function clinically practicable. We describe a system built from a commercially available airway gas monitor and off the shelf computer and data-acquisition hardware.
METHODS: Analog data for gas flow rate, O2, and CO2 concentrations are introduced into a computer through an analog-to-digital conversion board. Oxygen uptake (VO2) and carbon dioxide output (VCO2) are calculated for each breath. Inspired minus expired concentrations for O2 and CO2 are displayed simultaneously with the expired gas flow rate curve for each breath. Dead-space and alveolar ventilation are calculated for each breath and readily appreciated from the display.
RESULTS: Graphs illustrating the function of the system are presented for the following clinical scenarios; upper airway obstruction, bronchospasm, bronchopleural fistula, pulmonary perfusion changes and inadequate oxygen delivery.
CONCLUSIONS: This paper describes a real-time, single breath pulmonary monitoring system that displays three parameters graphed against time: expired flow rate, oxygen uptake and carbon dioxide production. This system allows for early and rapid recognition of treatable conditions that may lead to adverse events without any additional patient measurements or invasive procedures. Monitoring systems similar to the one described in this paper may lead to a higher level of patient safety without any additional patient risk.

Entities:  

Mesh:

Year:  2002        PMID: 12455743     DOI: 10.1023/a:1020731307959

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  16 in total

1.  End-tidal carbon dioxide concentration, carbon dioxide production, heart rate, and blood pressure as indicators of induced hyperthermia.

Authors:  V de las Alas; W D Voorhees; L A Geddes; J D Bourland; W E Schoenlein
Journal:  J Clin Monit       Date:  1990-07

2.  Expiratory flow rate curves for monitoring upper and lower airway obstruction during anesthesia.

Authors:  K R Davies; F E Noe; R E Davies; M G Busby; R Case
Journal:  J Clin Monit       Date:  1991-10

3.  Aspects of on-line digital integration of pulmonary gas transfer.

Authors:  T E Bernard
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1977-08

4.  Dedicated monitoring of anesthetic and respiratory gases by Raman scattering.

Authors:  R A VanWagenen; D R Westenskow; R E Benner; D E Gregonis; D L Coleman
Journal:  J Clin Monit       Date:  1986-10

5.  On-line computer analysis and breath-by-breath graphical display of exercise function tests.

Authors:  W L Beaver; K Wasserman; B J Whipp
Journal:  J Appl Physiol       Date:  1973-01       Impact factor: 3.531

6.  Simultaneous computer-calculated carbon dioxide and oxygen direct Fick and dye dilution measurements of cardiac output in dogs.

Authors:  F E Noe; A J Whitty; K R Davies
Journal:  Acta Anaesthesiol Scand       Date:  1981-02       Impact factor: 2.105

7.  Deadspace, invasive and non-invasive.

Authors:  R Fletcher
Journal:  Br J Anaesth       Date:  1985-03       Impact factor: 9.166

8.  Monitoring of the inspired and end-tidal oxygen, carbon dioxide, and nitrous oxide concentrations: clinical applications during anesthesia and recovery.

Authors:  K Linko; M Paloheimo
Journal:  J Clin Monit       Date:  1989-07

9.  Single-breath measurements of pulmonary oxygen uptake and gas flow rates for ventilator management in ARDS.

Authors:  J E Szalados; F E Noe; M G Busby; P G Boysen
Journal:  Chest       Date:  2000-06       Impact factor: 9.410

10.  Noninvasive measurement of pulmonary gas exchange during general anesthesia.

Authors:  F E Noe; A J Whitty; K R Davies; B L Wickham
Journal:  Anesth Analg       Date:  1980-04       Impact factor: 5.108

View more
  1 in total

1.  A new calibration method that compensates for the effects of O2 and N2 on infrared CO2 analysers.

Authors:  Yongquan Tang; Martin J Turner; A Barry Baker
Journal:  J Clin Monit Comput       Date:  2006-06-08       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.