Literature DB >> 12453702

True aneurysm in a femoro-popliteal dacron graft -- a case report and literature review.

Harmeet S Khaira1, Hunaid Vohra.   

Abstract

Infection and anastomotic pseudo-aneurysm formation are the usually reported complications in the use of dacron prosthesis in arterial by-pass surgery. We report a case of true aneurysm formation in the body of a knitted dacron graft used to by-pass a symptomatic above knee occlusion of the superficial femoral artery when suitable long saphenous vein was not available. This was diagnosed 10 years after surgery. A true aneurysm may be a result of pre-implantation trauma to the graft or to late fibre degeneration. Microscopic examination revealed that the dacron fibres had stretched to form a local aneurysm before rupturing to form an associated false aneurysm. Two other areas of the graft had small saccular aneurysms without rupture. The damaged portion was excised and replaced by an interposition graft of the same material.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12453702     DOI: 10.1016/s0967-2109(02)00064-9

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  5 in total

1.  Treatment of Dacron Grafting Dilatation with Endovascular Stent Graftıng.

Authors:  Murat Ugurlucan; Didem Melis Oztas; Yilmaz Onal; Cagla Canbay; Omer Ali Sayin; Mehmet Barburoglu; Muslum Ercument Filik; Deniz Ocal; Mehmet Buget; Bulent Acunas; Ufuk Alpagut
Journal:  Aorta (Stamford)       Date:  2016-10-01

2.  Nonanastomotic rupture of thoracic aortic Dacron graft treated by endovascular stent graft placement.

Authors:  Seiichi Yamaguchi; Toshihisa Asakura; Sumio Miura; Takao Ohki; Yuji Kanaoka; Hiroki Ohta; Noriyuki Yajima; Mitsuru Nakaya
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-09-25

Review 3.  [Graft aneurysms as long-term complication of polyester prostheses and their management : Brief review based on a systematic review of the literature].

Authors:  U Barth; K Wasseroth; F Meyer
Journal:  Chirurg       Date:  2018-03       Impact factor: 0.955

4.  Clinical analysis of non-anastomotic aneurysms of implanted prosthetic grafts.

Authors:  Satoshi Yamamoto; Katsuyuki Hoshina; Hideo Kimura; Hiroyuki Okamoto; Kunihiro Shigematsu; Tetsuro Miyata; Toshiaki Watanabe
Journal:  Surg Today       Date:  2014-04-03       Impact factor: 2.549

5.  Leaking pseudoaneurysm of lower limb saphenous vein graft: a rare complication and its successful treatment by endovascular embolization.

Authors:  Shaileshkumar Garge; Pooja Vyas; Krantikumar Rathod; Sunila Jaggi; Inder Talwar
Journal:  BJR Case Rep       Date:  2016-07-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.