Literature DB >> 12453125

Outcome of implant therapy in relation to experienced loss of periodontal bone support: a retrospective 5- year study.

Christoph R E Hardt1, Kerstin Gröndahl, Ulf Lekholm, Jan L Wennström.   

Abstract

PURPOSE: The aim of this retrospective study was to analyse bone level alterations over a 5-year period at implants in the maxillary posterior segments in patients with varying experience of periodontal bone loss in the natural dentition before implant placement.
MATERIALS AND METHODS: 97 partially dentate patients with a total of 346 Brånemark oral implants in the maxillary posterior segments were included. By assessing the degree of radiographic marginal bone loss in the remaining natural dentition at time of the implant therapy, an age-related bone loss score (ArB-score) was calculated for description of the patient's experience of periodontal destruction. The two end quartiles of the distribution of the subjects with regard to the ArB-score were defined as Non-Perio subjects and Perio subjects, respectively. The primary outcome variables were implant losses (implant failures) and radiographic peri-implant bone loss over the 5-year observation period.
RESULTS: A total of 18 implants were lost during the 5 years, resulting in an overall failure rate of 5.2%. The corresponding failure rate was 3.3% for the Non-Perio and 8.0% for the Perio patients. The peri-implant bone loss from the time of abutment connection to 5 years averaged 1.8 mm (SD 0.7). Of the patients, 34% showed a mean bone loss of > 2 mm and 39% of all implants had experienced a bone loss of 2 mm at the 5-year examination. The Non-Perio and Perio patients showed a mean bone loss of 1.7 mm (0.8) and 2.2 mm (0.8), respectively. Multiple regression analysis revealed a statistically significant relationship between the ArB-score and the peri-implant bone level change from abutment connection to 5 years (P < 0.05). In all, 64% of Perio patients had a mean peri-implant bone loss of > 2 mm from the time of abutment connection, compared to 24% for the Non-Perio patients (P < 0.01). The percentage of implants showing 2 mm of bone loss between abutment connection and 5 years was 62% and 44% in the Perio and Non-Perio groups, respectively (P = 0.055).
CONCLUSION: The results indicate that longitudinal bone loss around implants is correlated to previous experience of loss of periodontal bone support and that periodontitis susceptible subjects may show an increased implant failure rate.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12453125     DOI: 10.1034/j.1600-0501.2002.130507.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  19 in total

1.  Re-stability of dental implants following treatment of peri-implantitis.

Authors:  Fawad Javed; Hamza Ather Hussain; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-09-16

2.  Reporting of dental status from full-arch radiographs: Descriptive analysis and methodological aspects.

Authors:  Fabian Huettig; Detlef Axmann
Journal:  World J Clin Cases       Date:  2014-10-16       Impact factor: 1.337

3.  Effects of coating a titanium alloy with fibronectin on the expression of osteoblast gene markers in the MC3T3 osteoprogenitor cell line.

Authors:  Bruce E Rapuano; Kyle M Hackshaw; Hannes C Schniepp; Daniel E MacDonald
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Sep-Oct       Impact factor: 2.804

4.  Titanium alloy surface oxide modulates the conformation of adsorbed fibronectin to enhance its binding to α(5) β(1) integrins in osteoblasts.

Authors:  Bruce E Rapuano; Jani J E Lee; Daniel E MacDonald
Journal:  Eur J Oral Sci       Date:  2012-05-08       Impact factor: 2.612

5.  Surface oxide net charge of a titanium alloy: comparison between effects of treatment with heat or radiofrequency plasma glow discharge.

Authors:  Daniel E MacDonald; Bruce E Rapuano; Hannes C Schniepp
Journal:  Colloids Surf B Biointerfaces       Date:  2010-09-28       Impact factor: 5.268

6.  Heat and radiofrequency plasma glow discharge pretreatment of a titanium alloy: evidence [corrected] for enhanced osteoinductive properties.

Authors:  Bruce E Rapuano; Herman Singh; Adele L Boskey; Stephen B Doty; Daniel E MacDonald
Journal:  J Cell Biochem       Date:  2013-08       Impact factor: 4.429

7.  Structure-activity relationship of human bone sialoprotein peptides.

Authors:  Bruce E Rapuano; Daniel E MacDonald
Journal:  Eur J Oral Sci       Date:  2013-09-17       Impact factor: 2.612

8.  Heat and radiofrequency plasma glow discharge pretreatment of a titanium alloy promote bone formation and osseointegration.

Authors:  Daniel E MacDonald; Bruce E Rapuano; Parth Vyas; Joseph M Lane; Kathleen Meyers; Timothy Wright
Journal:  J Cell Biochem       Date:  2013-10       Impact factor: 4.429

9.  Correlation between clinical parameters characterising peri-implant and periodontal health: a practice-based research in Spain in a series of patients with implants installed 4-5 years ago.

Authors:  Roberto Lopez-Piriz; Araceli Morales; Maria-Jose Giménez; Antonio Bowen; Rafael Carroquino; Lorenzo Aguilar; Ignacio Corral; Cora del Val; Inmaculada González; Luis-Maria Ilzarbe; Juan-Ramon Maestre; Esteban Padullés; Francisco Torres-Lear; Juan-Jose Granizo; Fidel San-Román; Sofia Hernández; Jose Prieto
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-09-01

10.  Heat or radiofrequency plasma glow discharge treatment of a titanium alloy stimulates osteoblast gene expression in the MC3T3 osteoprogenitor cell line.

Authors:  Bruce E Rapuano; Kyle Hackshaw; Daniel E Macdonald
Journal:  J Periodontal Implant Sci       Date:  2012-06-30       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.