Literature DB >> 12453024

A simple model to demonstrate the electronic apex locator.

A C Tinaz1, T Alaçam, O Topuz.   

Abstract

AIM: To describe and evaluate a newly developed model for demonstrating and teaching the use of electronic apex locators.
SUMMARY: A phantom model, master jaw model and extracted human teeth were used to construct the demonstration model with alginate impression material as the periapical conductive medium. The model was validated in a series of length determinations with apical foramina enlarged to 0.20, 0.30 and 0.45 mm diameter, and the stability of the model was evaluated up to 45 h after construction. All evaluations were conducted with the Root ZX apex locator with 2.65 and 5.25% NaOCl in the canals. Most length measurements were within 1 mm of actual root length (range: -2.2 to +0.21 mm) and did not change significantly over 45 h for teeth with foramina of 0.3 mm or less. Measurements for teeth with wide (0.45 mm) apices were stable up to 28 h. NaOCl concentration did not significantly affect the readings. KEY LEARNING POINTS: A simple, inexpensive model can be manufactured from plastic dental jaws, natural teeth and alginate impression material to demonstrate electronic working length measurement. The model is stable for many hours and provides consistent results with different concentrations of NaOCl in the canal and various apical diameters. The model is a useful teaching aid but needs further evaluation and refinement before use in research applications.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12453024     DOI: 10.1046/j.1365-2591.2002.00576.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  5 in total

1.  Accuracy of two different apex locators in primary teeth with and without root resorption.

Authors:  Haluk Bodur; Mesut Odabaş; Ozlem Tulunoğlu; Ali Cemal Tinaz
Journal:  Clin Oral Investig       Date:  2007-11-20       Impact factor: 3.573

2.  Evaluation of the Working Length Determination Accuracy by Cone-beam Computed Tomography in Primary Teeth.

Authors:  John Shibin; Prathima Gs; Suganya M; Nandhakumar S; Sanguida Adimoulame; Kavitha M
Journal:  Int J Clin Pediatr Dent       Date:  2022

3.  An Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants.

Authors:  Ashwini B Prasad; Srivastava Harshit; Srivastava Arora Aastha; Raisingani Deepak
Journal:  Ethiop J Health Sci       Date:  2016-09

4.  The effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study.

Authors:  Shiva Sadeghi; Masoomeh Abolghasemi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2008-05-15

5.  Working Length Determination of Root Canal of Young Permanent Tooth: An In vitro Study.

Authors:  A Diwanji; As Rathore; R Arora; V Dhar; A Madhusudan; J Doshi
Journal:  Ann Med Health Sci Res       Date:  2014-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.