Literature DB >> 12450170

Soft tissue response of the rabbit larynx to Gore-Tex implants.

Steve Cashman1, C Blake Simpson, H Stan McGuff.   

Abstract

The use of Gore-Tex (expanded polytetrafluoroethylene) for medialization laryngoplasty has recently been described. Clinically, this laryngeal implant has performed well, but no animal studies evaluating the use of this implant in the larynx have been published. This study examines the gross and histologic response of the rabbit larynx to the Gore-Tex implant. Five rabbits underwent bilateral medialization with the Gore Thyroplasty Device. The vocal folds were left innervated and mobile. After 6 months, the rabbits were painlessly sacrificed and the implants were evaluated by gross inspection and histologic examination. No gross changes to the glottis occurred, and the implants were easily removed with gentle traction. A modest inflammatory response with a thin fibrous capsule was present around the implant. Foreign body giant cells were observed at the interface of the implant with the tissue. No migration or extrusion of the implant was observed. These results suggest that Gore-Tex is biocompatible in the rabbit larynx.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12450170     DOI: 10.1177/000348940211101105

Source DB:  PubMed          Journal:  Ann Otol Rhinol Laryngol        ISSN: 0003-4894            Impact factor:   1.547


  4 in total

1.  Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(R)) implantation.

Authors:  K Rajkumar; Hs Khalil; M Elloy; E Sheffield; Dl Baldwin
Journal:  BMC Ear Nose Throat Disord       Date:  2005-01-21

2.  Combined laryngeal inflammation and trauma mediate long-lasting immunoreactivity response in the brainstem sensory nuclei in the rat.

Authors:  Kristina Simonyan; Xin Feng; Victor M Henriquez; Christy L Ludlow
Journal:  Front Integr Neurosci       Date:  2012-11-15

3.  Surgical procedures for voice restoration.

Authors:  Tadeus Nawka; Werner Hosemann
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2005-09-28

4.  Comparison of lyophilized glutaraldehyde-preserved bovine pericardium with different vascular prostheses for use as vocal cords implants: experimental study.

Authors:  J Raúl Olmos-Zuñiga; Rogelio Jasso-Victoria; Miguel Gaxiola-Gaxiola; Avelina Sotres-Vega; Claudia Hernández-Jiménez; Matilde Baltazares-Lipp; Fernando Arredondo del Bosque; Patricio Santillan-Doherty
Journal:  Biomed Res Int       Date:  2015-05-13       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.