Literature DB >> 12449204

Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption.

Alexander R Vaccaro1, John A Carrino, Benjamin H Venger, Todd Albert, Peter M Kelleher, Alan Hilibrand, Kush Singh.   

Abstract

OBJECT: Anterior cervical discectomy and fusion (ACDF) is a widely accepted treatment for anterior degenerative or traumatic instability of the cervical spine. To reduce or eliminate complications such as implant migration and failure, imaging degradation, and fusion stress shielding that are occasionally associated with spinal instrumentation, attention has been given to the use of bioresorbable anterior cervical plate (ACP) devices. This paper is a preliminary report of a retrospective series in which a resorbable mesh and screw system was used for graft containment in single-level ACDF.
METHODS: A review of patient charts and imaging studies was conducted to determine functional outcome, fusion success, and potential soft-tissue reaction to implant resorption. Nine patients with a cervical degenerative disc disease or traumatic disc disruption were treated between October 2001 and March 2002. Follow up averaged 206 days. Eight patients were found to have an excellent result, one patient had a good result, and no patients had a satisfactory or poor result. At the time of follow-up examination, 77% of patients were found to have a radiographically solid fusion. The two patients without a solid fusion were examined only an average 8 months postoperatively and manifested no symptoms related to fusion nonhealing. No significant soft-tissue reaction was noted clinically or radiographically in any of the patients.
CONCLUSIONS: The results of this preliminary study indicate that bioresorbable ACP systems for single-level ACDF are both safe and effective.

Entities:  

Mesh:

Year:  2002        PMID: 12449204     DOI: 10.3171/spi.2002.97.4.0473

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  8 in total

1.  Comparison of a zero-profile anchored spacer (ROI-C) and the polyetheretherketone (PEEK) cages with an anterior plate in anterior cervical discectomy and fusion for multilevel cervical spondylotic myelopathy.

Authors:  Yijie Liu; Heng Wang; Xuefeng Li; Jie Chen; Han Sun; Genlin Wang; Huilin Yang; Weimin Jiang
Journal:  Eur Spine J       Date:  2016-03-11       Impact factor: 3.134

2.  The use of BoneWelding® technology in spinal surgery: an experimental study in sheep.

Authors:  Dorothee Heidenreich; Jens D Langhoff; Katja Nuss; Katharina Kluge; Käthi Kämpf; Katalin Zlinsky; Monika Hilbe; Jörg Mayer; Brigitte von Rechenberg
Journal:  Eur Spine J       Date:  2011-04-27       Impact factor: 3.134

3.  Absorbable self-reinforced polylactide (SR-PLLA) rods vs rigid rods (K-wire) in spinal fusion: an experimental study in rabbits.

Authors:  Murat Bezer; Yakup Yildirim; Bülent Erol; Osman Güven
Journal:  Eur Spine J       Date:  2004-09-18       Impact factor: 3.134

Review 4.  Current concepts of anterior cervical discectomy and fusion: a review of literature.

Authors:  Kyung-Jin Song; Byeong-Yeol Choi
Journal:  Asian Spine J       Date:  2014-08-19

5.  Application of bioabsorbable screw fixation for anterior cervical decompression and bone grafting.

Authors:  Bo Zhao; Xiaowen Qiu; Dong Wang; Haopeng Li; Xijing He
Journal:  Clinics (Sao Paulo)       Date:  2016-07       Impact factor: 2.365

6.  Clinical effects of the bridge-type ROI-C interbody fusion cage system in the treatment of cervical spondylosis with osteoporosis.

Authors:  Yuluo Rong; Yongjun Luo; Wei Liu; Fangyi Gong; Pengyu Tang; Weihua Cai
Journal:  Clin Interv Aging       Date:  2018-12-14       Impact factor: 4.458

7.  The role of matrix metalloproteinase 14 polymorphisms in susceptibility to intervertebral disc degeneration in the Chinese Han population.

Authors:  Jianfeng Zhang; Xiujiang Sun; Jing Liu; Jianqing Liu; Binghua Shen; Lin Nie
Journal:  Arch Med Sci       Date:  2015-08-11       Impact factor: 3.318

8.  Zero-profile implant (Zero-p) versus plate cage benezech implant (PCB) in the treatment of single-level cervical spondylotic myelopathy.

Authors:  ZhiDong Wang; RuoFu Zhu; HuiLin Yang; MinJie Shen; Genlin Wang; Kangwu Chen; Minfeng Gan; Mao Li
Journal:  BMC Musculoskelet Disord       Date:  2015-10-12       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.