Literature DB >> 12448421

Fabrication of poly(ethylene glycol) hydrogel microstructures using photolithography.

A Revzin1, R J Russell, V K Yadavalli, W G Koh, C Deister, D D Hile, M B Mellott, M V Pishko.   

Abstract

The fabrication of hydrogel microstructures based upon poly(ethylene glycol) diacrylates, dimethacrylates, and tetraacrylates patterned photolithographically on silicon or glass substrates is described. A silicon/silicon dioxide surface was treated with 3-(trichlorosilyl)propyl methacrylate to form a self-assembled monolayer (SAM) with pendant acrylate groups. The SAM presence on the surface was verified using ellipsometry and time-of-flight secondary ion mass spectrometry. A solution containing an acrylated or methacrylated poly(ethylene glycol) derivative and a photoinitiator (2,2-dimethoxy-2-phenylacetophenone) was spin-coated onto the treated substrate, exposed to 365 nm ultraviolet light through a photomask, and developed with either toluene, water, or supercritical CO2. As a result of this process, three-dimensional, cross-linked PEG hydrogel microstructures were immobilized on the surface. Diameters of cylindrical array members were varied from 600 to 7 micrometers by the use of different photomasks, while height varied from 3 to 12 micrometers, depending on the molecular weight of the PEG macromer. In the case of 7 micrometers diameter elements, as many as 400 elements were reproducibly generated in a 1 mm2 square pattern. The resultant hydrogel patterns were hydrated for as long as 3 weeks without delamination from the substrate. In addition, micropatterning of different molecular weights of PEG was demonstrated. Arrays of hydrogel disks containing an immobilized protein conjugated to a pH sensitive fluorophore were also prepared. The pH sensitivity of the gel-immobilized dye was similar to that in an aqueous buffer, and no leaching of the dye-labeled protein from the hydrogel microstructure was observed over a 1 week period. Changes in fluorescence were also observed for immobilized fluorophore labeled acetylcholine esterase upon the addition of acetyl acholine.

Entities:  

Keywords:  NASA Discipline Life Sciences Technologies; Non-NASA Center

Mesh:

Substances:

Year:  2001        PMID: 12448421     DOI: 10.1021/la010075w

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  50 in total

1.  Benchtop fabrication of PDMS microstructures by an unconventional photolithographic method.

Authors:  Chang Mo Hwang; Woo Young Sim; Seung Hwan Lee; Amir M Foudeh; Hojae Bae; Sang-Hoon Lee; Ali Khademhosseini
Journal:  Biofabrication       Date:  2010-09-24       Impact factor: 9.954

2.  Composite Scaffolds of Interfacial Polyelectrolyte Fibers for Temporally Controlled Release of Biomolecules.

Authors:  Marie Francene A Cutiongco; Benjamin Kim Kiat Teo; Evelyn King Fai Yim
Journal:  J Vis Exp       Date:  2015-08-19       Impact factor: 1.355

3.  Production of Uniform 3D Microtumors in Hydrogel Microwell Arrays for Measurement of Viability, Morphology, and Signaling Pathway Activation.

Authors:  Manjulata Singh; David A Close; Shilpaa Mukundan; Paul A Johnston; Shilpa Sant
Journal:  Assay Drug Dev Technol       Date:  2015-08-14       Impact factor: 1.738

4.  Fabrication of Poly(ethylene glycol) Hydrogel Structures for Pharmaceutical Applications using Electron beam and Optical Lithography.

Authors:  Misuk Bae; Ralu Divan; Kamlesh J Suthar; Derrick C Mancini; Richard A Gemeinhart
Journal:  J Vac Sci Technol B Nanotechnol Microelectron       Date:  2010-12-03

5.  Electrochemical biosensors for on-chip detection of oxidative stress from immune cells.

Authors:  Jun Yan; Valber A Pedrosa; James Enomoto; Aleksandr L Simonian; Alexander Revzin
Journal:  Biomicrofluidics       Date:  2011-09-20       Impact factor: 2.800

6.  Immobilizing enzymes onto electrode arrays by hydrogel photolithography to fabricate multi-analyte electrochemical biosensors.

Authors:  Jun Yan; Valber A Pedrosa; Aleksandr L Simonian; Alexander Revzin
Journal:  ACS Appl Mater Interfaces       Date:  2010-03       Impact factor: 9.229

7.  Stop-flow lithography to generate cell-laden microgel particles.

Authors:  Priyadarshi Panda; Shamsher Ali; Edward Lo; Bong Geun Chung; T Alan Hatton; Ali Khademhosseini; Patrick S Doyle
Journal:  Lab Chip       Date:  2008-05-22       Impact factor: 6.799

Review 8.  Development of hydrogel-based keratoprostheses: a materials perspective.

Authors:  David Myung; Pierre-Emile Duhamel; Jennifer R Cochran; Jaan Noolandi; Christopher N Ta; Curtis W Frank
Journal:  Biotechnol Prog       Date:  2008-04-19

9.  Biochemically and topographically engineered poly(ethylene glycol) diacrylate hydrogels with biomimetic characteristics as substrates for human corneal epithelial cells.

Authors:  B Yañez-Soto; S J Liliensiek; C J Murphy; P F Nealey
Journal:  J Biomed Mater Res A       Date:  2012-12-18       Impact factor: 4.396

10.  Patterned Surface Energy in Elastomeric Molds as a Generalized Approach to Polymer Particle Fabrication.

Authors:  Samuel D Oberdick; Gary Zabow
Journal:  ACS Appl Polym Mater       Date:  2020
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.