Literature DB >> 12445621

Mechanical compliance of the endocardium.

Young Bin Choy1, Hong Cao, Supan Tungjitkusolmun, Jang-Zern Tsai, Dieter Haemmerich, Vicken R Vorperian, John G Webster.   

Abstract

Radio-frequency (RF) ablation is an accepted treatment for cardiac arrhythmias related to abnormal focal cardiac substrate. The penetration depth of the electrode into the endocardium affects lesion size, a critical determinant of success of RF ablation. We measured the relation between the mechanical compliance and the penetration depth of RF ablation catheter electrode at frequently ablated areas of the endocardium and examined the influence of time after death on mechanical properties of the tissue. We measured force versus time for eight insertion depths of the catheter electrode into full-thickness endocardial samples derived from the mitral valve annulus, the left ventricular free wall and the tricuspid valve annulus. We varied the time after death at 15, 40 min, 3, 8, and 18 h and repeated our measurements. At 15 min after death, the first 0.5mm penetration depth caused the fastest relaxation at 55 s. Force decay decreased dramatically at 15 min after death as the penetration depth increased from 0.5 to 4mm. We used the force data sampled at 60s after insertion to approximate the elasticity. We observed the relations between the force versus the insertion depth. The force increased by a factor of 5 for the mitral valve annulus and 8 for the left free wall from 15 min to 18 h. We derived coefficients of a second-order polynomial equation relating the force data to insertion depth with R(2)>0.99.

Entities:  

Mesh:

Year:  2002        PMID: 12445621     DOI: 10.1016/s0021-9290(02)00228-2

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Transversely isotropic properties of porcine liver tissue: experiments and constitutive modelling.

Authors:  C Chui; E Kobayashi; X Chen; T Hisada; I Sakuma
Journal:  Med Biol Eng Comput       Date:  2006-12-08       Impact factor: 2.602

Review 2.  Design and biocompatibility of endovascular aneurysm filling devices.

Authors:  Jennifer N Rodriguez; Wonjun Hwang; John Horn; Todd L Landsman; Anthony Boyle; Mark A Wierzbicki; Sayyeda M Hasan; Douglas Follmer; Jesse Bryant; Ward Small; Duncan J Maitland
Journal:  J Biomed Mater Res A       Date:  2014-08-04       Impact factor: 4.396

Review 3.  Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature.

Authors:  Chongjun Yang; Yu Xie; Shuang Liu; Dong Sun
Journal:  Sensors (Basel)       Date:  2018-02-12       Impact factor: 3.576

4.  Should fluid dynamics be included in computer models of RF cardiac ablation by irrigated-tip electrodes?

Authors:  Ana González-Suárez; Juan J Pérez; Enrique Berjano
Journal:  Biomed Eng Online       Date:  2018-04-20       Impact factor: 2.819

  4 in total