Literature DB >> 12443951

Differences between trunk sway characteristics on a foam support surface and on the Equitest ankle-sway-referenced support surface.

J H J Allum1, F Zamani, A L Adkin, A Ernst.   

Abstract

Clinicians have sought ways to increase trunk sway so that it is easily observed and a balance deficit more easily identified. One technique often used for this purpose is to reduce the efficacy of ankle proprioceptive inputs on sway. To achieve this reduction either a foam mat is used as an unstable support surface or the subject stands on a surface made unstable with servo-driven ankle-sway-referencing. The purpose of the current study was to investigate differences in trunk pitch and roll sway characteristics using these techniques. Trunk sway while standing quietly on two legs was measured in 25 normal subjects in the age range 20-35 years for three support-surface conditions. Each condition was tested twice for 20 s, once with eyes open and once with eyes closed. The three conditions were standing on a foam support surface, standing on a support surface with pitch (fore-aft) ankle-sway-referencing as used for the standard Sensory Organization Test (SOT) of the Neurocom Equitest System (SOT 4 and 5), and standing with roll (lateral) ankle-sway-referencing. The latter was achieved by having the subjects stand turned 90 degrees to the standard SOT position. Two angular velocity sensors mounted on a belt measured trunk sway in the pitch and roll directions. Trunk roll angle and angular velocity amplitudes for pitch sway-referencing were reduced compared to either the foam or roll sway-referencing conditions, but trunk pitch angle and angular velocities amplitudes were greater. For roll sway-referencing, the trunk roll angle was greater than for the other stimulus conditions. Analyses of the trunk sway velocity in the frequency domain indicated that ankle-sway-referencing in the pitch direction increased trunk pitch sway at 1 Hz and decreased trunk roll sway between 2 and 5 Hz compared to foam support frequency spectra. Roll ankle-sway-referencing decreased trunk roll between 2 and 4 Hz only. These results indicate that using a foam support surface provides multidirectional trunk sway with velocity content across all frequencies in the range 0.8-5.2 Hz. Roll ankle-sway-referencing, but not pitch ankle-sway-referencing, yields trunk sway with similar characteristics to those with foam. Pitch ankle-sway-referencing forces pitch trunk resonance to be around 1 Hz and yields very different trunk sway from that obtained with a foam support surface. Roll sway-referencing is an alternative means to test multidirectional control of sway. Clinically though, foam is simpler to use and provides a more difficult balance task for the patient.

Entities:  

Mesh:

Year:  2002        PMID: 12443951     DOI: 10.1016/s0966-6362(02)00011-5

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  19 in total

1.  Changes in multi-segmented body movements and EMG activity while standing on firm and foam support surfaces.

Authors:  P A Fransson; S Gomez; M Patel; L Johansson
Journal:  Eur J Appl Physiol       Date:  2007-05-15       Impact factor: 3.078

2.  Functional near-infrared spectroscopy (fNIRS) brain imaging of multi-sensory integration during computerized dynamic posturography in middle-aged and older adults.

Authors:  Chia-Cheng Lin; Jeffrey W Barker; Patrick J Sparto; Joseph M Furman; Theodore J Huppert
Journal:  Exp Brain Res       Date:  2017-02-14       Impact factor: 1.972

3.  Influence of age and gender in the sensory analysis of balance control.

Authors:  Ana Faraldo-García; Sofía Santos-Pérez; Rosa Crujeiras-Casais; Torcuato Labella-Caballero; Andrés Soto-Varela
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-07-26       Impact factor: 2.503

4.  Is fall prevention by vitamin D mediated by a change in postural or dynamic balance?

Authors:  H A Bischoff-Ferrari; M Conzelmann; H B Stähelin; W Dick; M G Carpenter; A L Adkin; R Theiler; M Pfeifer; J H J Allum
Journal:  Osteoporos Int       Date:  2006-03-01       Impact factor: 4.507

5.  Estimating postural control with the balance rehabilitation unit: measurement consistency, accuracy, validity, and comparison with dynamic posturography.

Authors:  Khalid A Alahmari; Gregory F Marchetti; Patrick J Sparto; Joseph M Furman; Susan L Whitney
Journal:  Arch Phys Med Rehabil       Date:  2013-09-27       Impact factor: 3.966

6.  How to improve walking, balance and social participation following stroke: a comparison of the long term effects of two walking aids--canes and an orthosis TheraTogs--on the recovery of gait following acute stroke. A study protocol for a multi-centre, single blind, randomised control trial.

Authors:  Clare Maguire; Judith M Sieben; Florian Erzer; Beat Goepfert; Matthias Frank; Georg Ferber; Melissa Jehn; Arno Schmidt-Trucksäss; Robert A de Bie
Journal:  BMC Neurol       Date:  2012-03-30       Impact factor: 2.474

7.  Optimal motor control may mask sensory dynamics.

Authors:  Sean G Carver; Tim Kiemel; Noah J Cowan; John J Jeka
Journal:  Biol Cybern       Date:  2009-05-01       Impact factor: 2.086

8.  New analyses of the sensory organization test compared to the clinical test of sensory integration and balance in patients with benign paroxysmal positional vertigo.

Authors:  Ajitkumar P Mulavara; Helen S Cohen; Brian T Peters; Haleh Sangi-Haghpeykar; Jacob J Bloomberg
Journal:  Laryngoscope       Date:  2013-04-01       Impact factor: 3.325

9.  Support surface related changes in feedforward and feedback control of standing posture.

Authors:  Sambit Mohapatra; Komal K Kukkar; Alexander S Aruin
Journal:  J Electromyogr Kinesiol       Date:  2013-11-01       Impact factor: 2.368

10.  Age-adjusted normality patterns for posturography by Sway Star system.

Authors:  Ana Faraldo-García; Sofía Santos-Pérez; Torcuato Labella-Caballero; Rosa Crujeiras; Andrés Soto-Varela
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-04-30       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.