Literature DB >> 12439566

A novel vacuum device for extremity immobilisation during digital angiography: preliminary clinical experiences.

R J Bale1, C Lottersberger, M Vogele, A Prassl, B Czermak, A Dessl, R A Sweeney, P Waldenberger, W Jaschke.   

Abstract

Our objective was to develop and evaluate a non-invasive device for rigid immobilisation during extremity angiography. The patented BodyFix immobilisation device (Medical Intelligence, Schwabmünchen, Germany) consists of a vacuum pump connected to special cushions and a plastic foil that covers the body part to be immobilised. First, the patient's extremity is covered by a thin plastic bag and then wrapped in one of the cushions, placed on the top of the therapy couch, and covered with the plastic foil. The air is evacuated from the cushion under the covering foil by the vacuum pump, resulting a hardening of the cushion and thus immobilisation of the patient's extremity. The rigid immobilisation resulted in a complete absence of motion artefacts in the majority of patients. No pixeling of the images was required in any of the 100 patients vs 32% in the control group. Repetition of series could be avoided in all cases and a substantial increase in the quality of the images was obtained. Setup of the device takes an additional 1-2 min. Vacuum immobilisation allows for comfortable, effective immobilisation during digital subtraction angiography, eliminating motion artefacts. This device has become an indispensable tool in daily clinical routine at our department.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12439566     DOI: 10.1007/s00330-002-1492-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  3 in total

1.  Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests.

Authors:  Joachim Kettenbach; Gernot Kronreif; Michael Figl; Martin Fürst; Wolfgang Birkfellner; Rudolf Hanel; Helmar Bergmann
Journal:  Eur Radiol       Date:  2004-09-24       Impact factor: 5.315

2.  Accuracy of biopsy needle navigation using the Medarpa system--computed tomography reality superimposed on the site of intervention.

Authors:  M Fawad Khan; Selami Dogan; Adel Maataoui; Jessen Gurung; Mirko Schiemann; Hanns Ackermann; Stefan Wesarg; Georgios Sakas; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-03-08       Impact factor: 5.315

3.  Virtual digital subtraction angiography using multizone patch-based U-Net.

Authors:  Ryusei Kimura; Atsushi Teramoto; Tomoyuki Ohno; Kuniaki Saito; Hiroshi Fujita
Journal:  Phys Eng Sci Med       Date:  2020-10-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.