Ultrasound can predict regenerate stiffness in distraction osteogenesis.

Hermann J Bail1, Stefan Kolbeck, Gert Krummrey, Andreas Weiler, Henning J Windhagen, Karolin Hennies, Kirsten Raun, Michael J Raschke.   

Abstract

Assessing the regenerate strength in distraction osteogenesis is crucial for clinical treatment. Several methods have been used to achieve this, including plain radiography, digital radiography, quantitative computed tomography, dual energy xray absorptiometry, and ultrasound. The aim of the current study was to investigate the use of ultrasound in monitoring regenerate formation and to correlate this to biomechanical testing results. An osteotomy was done on the tibia of 30 Yucatan micropigs and an Ilizarov-type half-ring external fixator was mounted. After a 5-day latency period, the tibias were distracted for 10 days and then left to consolidate for 10 days. Seven ultrasound examinations were done during Day 15 through Day 25. After sacrifice, the bone mineral density was measured using quantitative computed tomography. Maximum load and torsional stiffness were measured and correlated with ultrasound measurements and bone mineral density. The ultrasound penetration depth and the bone mineral density correlated closely with torsional stiffness. Ultrasound can be a noninvasive predictor of bone regenerate strength in the early phase of distraction osteogenesis, which may reduce the need for radiographs.

Mesh:

Year:  2002        PMID: 12439281     DOI: 10.1097/00003086-200211000-00053

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Complications of Ilizarov leg lengthening: a comparative study between patients with leg length discrepancy and short stature.

Authors:  B Vargas Barreto; J Caton; Z Merabet; J C Panisset; J P Pracros
Journal:  Int Orthop       Date:  2006-10-12       Impact factor: 3.075

2.  Noninvasive quantitative assessment of bone healing after distraction osteogenesis.

Authors:  Oladapo M Babatunde; Austin T Fragomen; S Robert Rozbruch
Journal:  HSS J       Date:  2009-08-18

3.  Assessment of distraction callus in rabbits by monitoring of the electrical impedance of bone.

Authors:  Takashi Yoshida; Wook-Cheol Kim; Yoshinobu Oka; Naotake Yamada; Toshikazu Kubo
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

4.  Can the material properties of regenerate bone be predicted with non-invasive methods of assessment? Exploring the correlation between dual X-ray absorptiometry and compression testing to failure in an animal model of distraction osteogenesis.

Authors:  Fergal Monsell; Andrew William Hughes; James Turner; Michael C Bellemore; Lynne Bilston
Journal:  Strategies Trauma Limb Reconstr       Date:  2014-03-05

5.  Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model.

Authors:  Beth Lineham; Todd Stewart; Paul Harwood
Journal:  Strategies Trauma Limb Reconstr       Date:  2018-02-02

6.  Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study.

Authors:  Beth Lineham; Todd Stewart; John Ward; Paul Harwood
Journal:  Strategies Trauma Limb Reconstr       Date:  2021 Sep-Dec