Literature DB >> 12439268

Subchondral mineralization patterns of the glenoid after tear of the supraspinatus.

H Anetzberger1, C Schulz, M Pfahler, H J Refior, M Müller-Gerbl.   

Abstract

Clinical experience has shown that in many cases of rupture of the supraspinatus tendon the head of the humerus shifts upward against the acromion. This implicates alterations in the stress acting on the joint surface. Accordingly, this should be reflected by changes in the distribution of the subchondral mineralization on the glenoid. Computed tomography osteoabsorptiometry was used to evaluate the distribution patterns on the subchondral bone plate of the glenoid in 67 human shoulders. The position of the two most frequent density maxima was determined by a standard procedure. In macroscopically normal specimens (n = 24) every case had an anterosuperior density maximum and the majority (75%) also had a posterior positioned maximum. In some instances a third maximum, placed centrally (17%) or in an anteroinferior position (4%) was seen. In shoulders with a torn supraspinatus tendon (n = 43) a third density maximum frequently appeared in the center of the glenoid (42%); however, most notable was a significant change of the posterior maximum position toward central and superior. With increasing size of the tendon defect an extension of the shift of the posterior maximum (superiorly and centrally) was observed in contrast to the constant anterior maximum. The changes in the distribution of glenoid subchondral bone mineralization in shoulders with a supraspinatus tear must be regarded as a morphologic parameter for the altered long-term stress acting on the joint surface.

Entities:  

Mesh:

Year:  2002        PMID: 12439268     DOI: 10.1097/00003086-200211000-00040

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

1.  Anatomical considerations regarding the "bare spot" of the glenoid cavity.

Authors:  F Aigner; S Longato; H Fritsch; F Kralinger
Journal:  Surg Radiol Anat       Date:  2004-02-11       Impact factor: 1.246

2.  A prospective morphological study of facet joint integrity following intervertebral disc replacement with the CHARITE Artificial Disc.

Authors:  Hans Trouillier; P Kern; H J Refior; M Müller-Gerbl
Journal:  Eur Spine J       Date:  2005-09-07       Impact factor: 3.134

3.  Bone mineralization changes of the glenoid in shoulders with symptomatic rotator cuff tear.

Authors:  Yohei Harada; Shin Yokoya; Yuji Akiyama; Yu Mochizuki; Mitsuo Ochi; Nobuo Adachi
Journal:  Int Orthop       Date:  2018-06-06       Impact factor: 3.075

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.