Literature DB >> 12439122

Diagnostic accuracy of a rapid urine-screening test (Multistix8SG) in cirrhotic patients with spontaneous bacterial peritonitis.

Geoffroy Vanbiervliet1, Christian Rakotoarisoa, Jerôme Filippi, Olivier Guérin, Gustavo Calle, Patrick Hastier, Eugénia Mariné-Barjoan, Stéphane Schneider, Thierry Piche, Jean-Félix Broussard, Jean-François Dor, Sylvia Benzaken, Xavier Hébuterne, Patrick Rampal, Albert Tran.   

Abstract

OBJECTIVE: To assess the diagnostic accuracy of a rapid urine-screening test (Multistix8SG) for spontaneous bacterial peritonitis (SBP) in cirrhotic patients.
METHODS: Seventy-two consecutive patients (44 males, 28 females; mean age 61.6 years) with cirrhosis and ascites were included in the study. A diagnostic paracentesis was performed on hospital admission in all patients and 2 days after antibiotic treatment in the case of SBP (polymorphonuclear [PMN] count over 250/mm in ascitic fluid). Each fresh sample of ascitic fluid was also tested using the Multistix8SG urine test, and the results were scored as negative, trace or positive.
RESULTS: Nine of the 72 patients had SBP and the Multistix8SG urine test was positive. After 48 h of antibiotic therapy, the PMN count of three of these nine patients was still above 250/mm and the Multistix8SG test remained positive. In three other patients with SBP, the PMN count dropped below 250/mm and the Multistix8SG test result had become negative. Two of the nine SBP patients died before 48 h, and paracentesis was not performed in the ninth case. In the other 63 patients, the PMN count in ascitic fluid was below 250/mm; the Multistix8SG test revealed 17 trace results and 46 negative results. At the threshold of 250 PMN/mm in ascitic fluid, this test had a sensitivity and a specificity of 100%.
CONCLUSION: A positive Multistix8SG urine test result in ascitic fluid appears to be an indication for antibiotic treatment.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12439122     DOI: 10.1097/00042737-200211000-00015

Source DB:  PubMed          Journal:  Eur J Gastroenterol Hepatol        ISSN: 0954-691X            Impact factor:   2.566


  21 in total

1.  Efficacy of leukocyte esterase dipstick test as a rapid test in diagnosis of spontaneous bacterial peritonitis.

Authors:  Rungsun Rerknimitr; Worawut Rungsangmanoon; Pradermchai Kongkam; Pinit Kullavanijaya
Journal:  World J Gastroenterol       Date:  2006-11-28       Impact factor: 5.742

Review 2.  Current management of the complications of portal hypertension: variceal bleeding and ascites.

Authors:  Nina Dib; Frédéric Oberti; Paul Calès
Journal:  CMAJ       Date:  2006-05-09       Impact factor: 8.262

3.  Spontaneous bacterial peritonitis: a review of treatment options.

Authors:  Cesar Alaniz; Randolph E Regal
Journal:  P T       Date:  2009-04

4.  Ascitic fluid analysis for diagnosis and monitoring of spontaneous bacterial peritonitis.

Authors:  Oliviero Riggio; Stefania Angeloni
Journal:  World J Gastroenterol       Date:  2009-08-21       Impact factor: 5.742

5.  Diagnosis of spontaneous bacterial peritonitis: an update on leucocyte esterase reagent strips.

Authors:  Anastasios Koulaouzidis
Journal:  World J Gastroenterol       Date:  2011-03-07       Impact factor: 5.742

6.  Comments on the editorial by Riggio & Ageloni on the ascitic fluid analysis.

Authors:  Anastasios Koulaouzidis
Journal:  World J Gastroenterol       Date:  2009-12-28       Impact factor: 5.742

7.  Evaluation of leucocyte esterase reagent strip test for the rapid bedside diagnosis of spontaneous bacterial peritonitis.

Authors:  Sithara K Balagopal; Ashik Sainu; Varghese Thomas
Journal:  Indian J Gastroenterol       Date:  2010-05-05

8.  Multistix 10 SG Leukocyte Esterage Dipstick Testing in Rapid Bedside Diagnosis of Spontaneous Bacterial Peritonitis: A Prospective Study.

Authors:  Ashish K Jha; Dal C Kumawat; Yasvant K Bolya; Mahesh K Goenka
Journal:  J Clin Exp Hepatol       Date:  2012-09-21

9.  Diagnosis and management of bacterial infections in decompensated cirrhosis.

Authors:  Maria Pleguezuelo; Jose Manuel Benitez; Juan Jurado; Jose Luis Montero; Manuel De la Mata
Journal:  World J Hepatol       Date:  2013-01-27

10.  Measurement of calprotectin in ascitic fluid to identify elevated polymorphonuclear cell count.

Authors:  Emanuel Burri; Felix Schulte; Jürgen Muser; Rémy Meier; Christoph Beglinger
Journal:  World J Gastroenterol       Date:  2013-04-07       Impact factor: 5.742