Literature DB >> 12438829

MADIT-II: clinical implications.

Arthur J Moss1, James Daubert, Wojciech Zareba.   

Abstract

The MADIT-II trial showed that in patients with a prior myocardial infarction and ejection fraction </=0.30, prophylactic implantation of a defibrillator improves survival with a 31% reduction in mortality during an average follow-up of 20 months. Electrophysiologic inducibility was positive in 36% of patients at the time of ICD implantation. Inducibility was associated with increased ICD utilization for ventricular tachycardia during long-term follow-up, and decreased utilization for ventricular fibrillation. These preliminary findings raise questions about the clinical usefulness of electrophysiologic testing as a risk stratifier in patients with advanced left ventricular dysfunction.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12438829     DOI: 10.1023/a:1021104929368

Source DB:  PubMed          Journal:  Card Electrophysiol Rev        ISSN: 1385-2264


  6 in total

Review 1.  Novel techniques for assessment of left ventricular systolic function.

Authors:  Sonal Chandra; Hicham Skali; Ron Blankstein
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

2.  Sleep quality and sleepiness in persons with implantable cardioverter defibrillators: outcome from a clinical randomized longitudinal trial.

Authors:  Selina Kikkenborg Berg; Melinda Higgins; Carolyn M Reilly; Jonathan J Langberg; Sandra B Dunbar
Journal:  Pacing Clin Electrophysiol       Date:  2012-02-03       Impact factor: 1.976

3.  ICD shocks: not just the "straw that broke the camel's back".

Authors:  Harikrishna Tandri
Journal:  Heart Rhythm       Date:  2010-02-24       Impact factor: 6.343

4.  Implantable cardioverter defibrillator implantation in children in The Netherlands.

Authors:  A Derk Jan Ten Harkel; Nico A Blom; Annette G Reimer; Raymond Tukkie; Narayanswami Sreeram; Margreet T E Bink-Boelkens
Journal:  Eur J Pediatr       Date:  2005-04-21       Impact factor: 3.183

Review 5.  Device based treatment of heart failure.

Authors:  A Y Patwala; D J Wright
Journal:  Postgrad Med J       Date:  2005-05       Impact factor: 2.401

6.  Impact of cardiac reverse remodeling after cardiac resynchronization therapy assessed by myocardial perfusion imaging on ventricular arrhythmia.

Authors:  Kuo-Feng Chiang; Guang-Uei Hung; Shih-Chung Tsai; Chien-Ming Cheng; Yu-Cheng Chang; Wan-Yu Lin; Yu-Cheng Hsieh; Tsu-Juey Wu; Shih-Ann Chen; Jin-Long Huang; Ying-Chieh Liao; Ji Chen
Journal:  J Nucl Cardiol       Date:  2016-03-15       Impact factor: 5.952

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.