Literature DB >> 12437962

Comparison of haemocompatibility improvement of four polymeric biomaterials by two heparinization techniques.

G P A Michanetzis1, N Katsala, Y F Missirlis.   

Abstract

Two surface heparinization procedures, introduced by Bamford and Al-Lamee (Polymer 22 (1996) 4885; 13 (1994) 2844) and Seifert et al. (J. Mater. Sci.: Mater. Med. 7 (1996) 465), respectively, were applied to four commercially available biomaterials (silicone rubber, polyethylene, polypropylene and polyvinylchloride) in order to compare their efficiency in improving haemocompatibility. The indirect method (Bamford and Al-Lamee) produced a much better heparinization yield-10.5% maximum, compared to the direct one (Seifert et al.), of only 0.20% maximum. Both methods provided a better response of the heparinized biomaterials compared to the uncoated ones in terms of platelet retention and a significantly better response in terms of activation of the coagulation system, suggesting that heparin molecules remained biologically functional in both cases. The results were particularly interesting in the case of polyvinylchloride where the maximum immobilization yield was obtained by the indirect method resulting also to a pronounced haemocompatibility improvement. Scanning electron microscopy studies confirmed adhered platelet morphology whereas atomic force microscopy was used to examine surface morphology of heparinized and reference materials surface.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12437962     DOI: 10.1016/s0142-9612(02)00382-4

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

Review 1.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

2.  Development of functionalized polyetherimide/polyvinylpyrrolidone membranes for application in hemodialysis.

Authors:  Alana Melo Dos Santos; Alberto Claudio Habert; Helen Conceição Ferraz
Journal:  J Mater Sci Mater Med       Date:  2017-07-25       Impact factor: 3.896

3.  The blood and vascular cell compatibility of heparin-modified ePTFE vascular grafts.

Authors:  Ryan A Hoshi; Robert Van Lith; Michele C Jen; Josephine B Allen; Karen A Lapidos; Guillermo Ameer
Journal:  Biomaterials       Date:  2012-10-12       Impact factor: 12.479

4.  Immobilized Carbonic Anhydrase on Hollow Fiber Membranes Accelerates CO(2) Removal from Blood.

Authors:  David T Arazawa; Heung-Il Oh; Sang-Ho Ye; Carl A Johnson; Joshua R Woolley; William R Wagner; William J Federspiel
Journal:  J Memb Sci       Date:  2012-02-13       Impact factor: 8.742

5.  Effect of Immobilized Antithrombin III on the Thromboresistance of Polycarbonate Urethane.

Authors:  Karin Lukas; Karin Stadtherr; Andre Gessner; Daniel Wehner; Thomas Schmid; Hans Peter Wendel; Christof Schmid; Karla Lehle
Journal:  Materials (Basel)       Date:  2017-03-24       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.