Literature DB >> 12433717

Restricted cross-reactivity of hybrid capture 2 with nononcogenic human papillomavirus types.

Philip E Castle1, Mark Schiffman, Robert D Burk, Sholom Wacholder, Allan Hildesheim, Rolando Herrero, M Concepcion Bratti, Mark E Sherman, Attila Lorincz.   

Abstract

Hybrid Capture 2 Test using probe B (HC2-B) is a clinical test for the detection of 13 human papillomavirus (HPV) types associated with cervical cancer (oncogenic types), but the potential clinical significance of HC2-B cross-reactivity with untargeted (nononcogenic) HPV types has not been fully evaluated. Thus, HC2-B test results on 954 clinical cervical specimens from a population-based natural history study of HPV in Costa Rica were compared with the data from testing of the same specimens twice by HPV type-specific MY09/MY11 L1 consensus primer PCR. Specimens positive by PCR for single HPV types not targeted by HC2-B were used for determining type-specific cross-reactivity. Effects of cross-reactivity on clinical performance were estimated by calculating sensitivity and specificity with and without cross-reactivity for the detection of high-grade cervical lesions. HC2-B tested positive for single infections by untargeted (cross-reactive) types 11, 53, 61, 66, 67, 70, 71, and 81. Cross-reactivity was strongly associated with PCR signal strength (P(Trend) = 0.0001) and cervical abnormalities (P = 0.0002, Pearson chi(2)). We estimated that HC2-B cross-reactivity resulted in minor changes in screening performance. Clinical sensitivity increased from 84.3% to 87.9%, clinical specificity decreased from 89.6% to 88.1%, and referral rates increased from 11.7% to 13.2% for detection of >or=cervical intraepithelial neoplasia grade 2. The clinical effect of cross-reactivity varied by cytologic interpretation. Among women with normal cytologic interpretations, cross-reactivity significantly improved the accuracy of identifying cytologically nonevident histology of >or=cervical intraepithelial neoplasia grade 2 because of increased sensitivity with maintained specificity. However, among women with equivocal or mildly abnormal cytologic interpretations, cross-reactivity decreased the accuracy of HPV testing because of substantial decreases in specificity. In summary, cross-reactivity with nononcogenic HPV types had little effect on the overall clinical performance of HC2-B as a general screening test, but reduction of cross-reactivity might improve the performance of HPV testing for triage of equivocal or mildly abnormal cytologic interpretations.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12433717

Source DB:  PubMed          Journal:  Cancer Epidemiol Biomarkers Prev        ISSN: 1055-9965            Impact factor:   4.254


  50 in total

1.  Pilot study of a commercialized human papillomavirus (HPV) genotyping assay: comparison of HPV risk group to cytology and histology.

Authors:  Philip E Castle; Mark Sadorra; Francisco Garcia; E Blair Holladay; Janet Kornegay
Journal:  J Clin Microbiol       Date:  2006-09-13       Impact factor: 5.948

2.  Comparison of the Digene HC2 assay and the Roche AMPLICOR human papillomavirus (HPV) test for detection of high-risk HPV genotypes in cervical samples.

Authors:  Maria T Sandri; Paola Lentati; Elvira Benini; Patrizia Dell'Orto; Laura Zorzino; Francesca M Carozzi; Patrick Maisonneuve; Rita Passerini; Michela Salvatici; Chiara Casadio; Sara Boveri; Mario Sideri
Journal:  J Clin Microbiol       Date:  2006-06       Impact factor: 5.948

3.  Human papillomavirus genotyping after denaturation of specimens for Hybrid Capture 2 testing: feasibility study for the HPV persistence and progression cohort.

Authors:  Brandon J LaMere; Janet Kornegay; Barbara Fetterman; Mark Sadorra; Jen Shieh; Philip E Castle
Journal:  J Virol Methods       Date:  2007-07-27       Impact factor: 2.014

4.  Cross-sectional comparison of an automated hybrid capture 2 assay and the consensus GP5+/6+ PCR method in a population-based cervical screening program.

Authors:  A T Hesselink; N W J Bulkmans; J Berkhof; A T Lorincz; C J L M Meijer; P J F Snijders
Journal:  J Clin Microbiol       Date:  2006-10       Impact factor: 5.948

5.  Human papillomavirus quantification in urine and cervical samples by using the Mx4000 and LightCycler general real-time PCR systems.

Authors:  Christopher Payan; Alexandra Ducancelle; Mohamed H Aboubaker; Julien Caer; Malena Tapia; Amelie Chauvin; Damien Peyronnet; Elodie Le Hen; Zohra Arab; Marie-Christine Legrand; Adissa Tran; Edith Postec; Françoise Tourmen; Martine Avenel; Chantal Malbois; Marie-Anne De Brux; Philippe Descamps; Francoise Lunel
Journal:  J Clin Microbiol       Date:  2007-01-17       Impact factor: 5.948

6.  Comparison of Onclarity Human Papillomavirus (HPV) Assay with Hybrid Capture II HPV DNA Assay for Detection of Cervical Intraepithelial Neoplasia Grade 2 and 3 Lesions.

Authors:  F Bottari; M Sideri; C Gulmini; S Igidbashian; A Tricca; C Casadio; S Carinelli; S Boveri; D Ejegod; J Bonde; M T Sandri
Journal:  J Clin Microbiol       Date:  2015-04-22       Impact factor: 5.948

7.  Vaginal self sampling versus physician cervical sampling for HPV among younger and older women.

Authors:  T Karwalajtys; M Howard; J W Sellors; J Kaczorowski
Journal:  Sex Transm Infect       Date:  2006-08       Impact factor: 3.519

8.  Assessment of a New Lower-Cost Real-Time PCR Assay for Detection of High-Risk Human Papillomavirus: Useful for Cervical Screening in Limited-Resource Settings?

Authors:  Joel Fokom Domgue; Mark Schiffman; Nicolas H Wentzensen; Julia C Gage; Philip E Castle; Tina R Raine-Bennett; Barbara Fetterman; Thomas Lorey; Nancy E Poitras; Brian Befano; Yi Xie; Lais S Miachon; Michael Dean
Journal:  J Clin Microbiol       Date:  2017-05-17       Impact factor: 5.948

9.  Optimal threshold for a positive hybrid capture 2 test for detection of human papillomavirus: data from the ARTISTIC trial.

Authors:  A Sargent; A Bailey; A Turner; M Almonte; C Gilham; H Baysson; J Peto; C Roberts; C Thomson; M Desai; J Mather; H Kitchener
Journal:  J Clin Microbiol       Date:  2009-12-09       Impact factor: 5.948

10.  Comparison of linear array and line blot assay for detection of human papillomavirus and diagnosis of cervical precancer and cancer in the atypical squamous cell of undetermined significance and low-grade squamous intraepithelial lesion triage study.

Authors:  Philip E Castle; Patti E Gravitt; Diane Solomon; Cosette M Wheeler; Mark Schiffman
Journal:  J Clin Microbiol       Date:  2007-11-07       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.