Literature DB >> 12432540

A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection.

Jan Lichtenberg1, Nico F de Rooij, Elisabeth Verpoorte.   

Abstract

We present a new approach for contactless conductivity detection for microchip-based capillary electrophoresis (CE). The detector integrates easily with well-known microfabrication techniques for glass-based microfluidic devices. Platinum electrodes are structured in recesses in-plane with the microchannel network after glass etching, which allows precise positioning and batch fabrication of the electrodes. A thin glass wall of 10-15 microm separates the electrodes and the buffer electrolyte in the separation channel to achieve the electrical insulation necessary for contactless operation. The effective separation length is 34 mm, with a channel width of 50 microm and depth of 12 microm. Microchip CE devices with conductivity detection were characterized in terms of sensitivity and linearity of response, and were tested using samples containing up to three small cations. The limit of detection for K+ (18 microM) is good, though an order of magnitude higher than for comparable capillary-based systems and one recently reported example of contactless conductivity on chip. However, an integrated field-amplified stacking step could be employed prior to CE to preconcentrate the sample ions by a factor of four.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12432540     DOI: 10.1002/1522-2683(200211)23:21<3769::AID-ELPS3769>3.0.CO;2-E

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  6 in total

1.  Microfluidic diagnostic tool for the developing world: contactless impedance flow cytometry.

Authors:  Sam Emaminejad; Mehdi Javanmard; Robert W Dutton; Ronald W Davis
Journal:  Lab Chip       Date:  2012-11-07       Impact factor: 6.799

2.  Development of a photothermal absorbance detector for use with microfluidic devices.

Authors:  Patty J Dennis; Erin Ferguson Welch; Jean Pierre Alarie; J Michael Ramsey; James W Jorgenson
Journal:  Anal Chem       Date:  2010-05-15       Impact factor: 6.986

Review 3.  Isotachophoresis: Theory and Microfluidic Applications.

Authors:  Ashwin Ramachandran; Juan G Santiago
Journal:  Chem Rev       Date:  2022-06-22       Impact factor: 72.087

4.  A Study on Double Inputs Direct Contact and Single Output Capacitively Coupled Conductivity Detector.

Authors:  Shuangfei Zhang; Hongyan Yuan; Dan Xiao
Journal:  Sensors (Basel)       Date:  2022-04-02       Impact factor: 3.576

5.  A plug-in electrophoresis microchip with PCB electrodes for contactless conductivity detection.

Authors:  Mingpeng Yang; Zhe Huang; Hui You
Journal:  R Soc Open Sci       Date:  2018-05-09       Impact factor: 2.963

6.  A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis.

Authors:  Jianjiao Wang; Yaping Liu; Wenhe He; Yuanfen Chen; Hui You
Journal:  Micromachines (Basel)       Date:  2022-02-28       Impact factor: 2.891

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.