Literature DB >> 12432537

Microchip-based amperometric immunoassays using redox tracers.

Joseph Wang1, Alfredo Ibáñez, Madhu Prakash Chatrathi.   

Abstract

A new chip-based electrochemical immunoassay protocol, based on the use of a ferrocene redox label, is described. Two reaction formats, based on direct (noncompetitive) and competitive modes of operation, were employed for illustrating the use of redox tracers in chip-based electrochemical immunoassays. The direct assay consisted of mixing the ferrocene-tagged antibody and the antigen analyte, a rapid electrophoretic separation of labeled free antibody and the labeled antigen/antibody complex, and a downstream anodic detection of the ferrocene tracer at gold-plated carbon screen-printed electrode detector. The competitive assay integrates precolumn reactions of the labeled antigen and the target antigen with the antibody with electrophoretic separation of the free and bound labeled antigens, along with amperometric detection of the redox tag. An internal standard has been used to normalize the peak area for the construction of calibration plots. Fundamental operating variables are examined and optimized. The use of a redox tracer offers the advantages of simplified protocol, wider linear range, higher stability, and higher separation efficiency compared to an analogous use of enzyme tags. The direct mouse-immunoglobulin G (IgG) assay and the competitive 3,3',5-triiodo-L-thyronine (T(3)) one were accomplished within less than 150 and 130 s (with field strengths of 256 and 192 V/cm), and offer minimum detectable concentrations of 2.5 x 10(-12) and 1 x1 0(-6) g/mL, respectively. Such use of redox labels for chip-based amperometric immunoassay protocols offers considerable promise for decentralized clinical or environmental testing.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12432537     DOI: 10.1002/1522-2683(200211)23:21<3744::AID-ELPS3744>3.0.CO;2-B

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  A homogeneous immunoassay of thyroxine based on microchip electrophoresis and chemiluminescence detection.

Authors:  Shulin Zhao; Yi-Ming Liu
Journal:  Methods Mol Biol       Date:  2013

2.  Chemiluminescent immunoassay of thyroxine enhanced by microchip electrophoresis.

Authors:  Yong Huang; Shulin Zhao; Ming Shi; Yi-Ming Liu
Journal:  Anal Biochem       Date:  2009-12-02       Impact factor: 3.365

Review 3.  Clinical analysis by microchip capillary electrophoresis.

Authors:  Sam F Y Li; Larry J Kricka
Journal:  Clin Chem       Date:  2005-11-18       Impact factor: 8.327

Review 4.  Antibody-Electroactive Probe Conjugates Based Electrochemical Immunosensors.

Authors:  Mateusz Kondzior; Iwona Grabowska
Journal:  Sensors (Basel)       Date:  2020-04-03       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.