Literature DB >> 12432534

A contactless conductivity detector for capillary electrophoresis: effects of the detection cell geometry on the detector performance.

Petr Tůma1, Frantisek Opekar, Karel Stulík.   

Abstract

The effect of the gap between the electrodes and of their width on the behavior of a capacitively wired contactless conductivity detector was studied. The results obtained have indicated that the detector response can be qualitatively described by a model based on the concept of the effective electrode width which is a complex parameter determined by the gap between the electrodes, the frequency of the input signal and the conductivity of the test solution. The detector sensitivity and the effect on the separation efficiency depend on the difference between the effective and geometric electrode widths. Higher detection sensitivities have been attained for detectors with wide electrodes operating at lower frequencies, however, better separation efficiencies have been achieved using detectors with narrow electrodes and higher operational frequencies. The noise increases with decreasing gap between the electrodes and increasing frequency, especially with detectors employing narrow electrodes.

Mesh:

Substances:

Year:  2002        PMID: 12432534     DOI: 10.1002/1522-2683(200211)23:21<3718::AID-ELPS3718>3.0.CO;2-U

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  Development of a photothermal absorbance detector for use with microfluidic devices.

Authors:  Patty J Dennis; Erin Ferguson Welch; Jean Pierre Alarie; J Michael Ramsey; James W Jorgenson
Journal:  Anal Chem       Date:  2010-05-15       Impact factor: 6.986

2.  3D-printed microchip electrophoresis device containing spiral electrodes for integrated capacitively coupled contactless conductivity detection.

Authors:  Brenda M C Costa; Aline G Coelho; Michael J Beauchamp; Jacob B Nielsen; Gregory P Nordin; Adam T Woolley; José A F da Silva
Journal:  Anal Bioanal Chem       Date:  2021-07-14       Impact factor: 4.142

3.  Investigation of the Effects of Electrode Geometry on the Performance of C4D Sensor with Radial Configuration.

Authors:  Qiang Huang; Junchao Huang; Yandan Jiang; Haifeng Ji; Baoliang Wang; Zhiyao Huang
Journal:  Sensors (Basel)       Date:  2021-06-29       Impact factor: 3.576

Review 4.  Contactless impedance sensors and their application to flow measurements.

Authors:  František Opekar; Petr Tůma; Karel Stulík
Journal:  Sensors (Basel)       Date:  2013-02-27       Impact factor: 3.576

  4 in total