Literature DB >> 12430611

Bead injection for surface enhanced Raman spectroscopy: automated on-line monitoring of substrate generation and application in quantitative analysis.

Maria José Ayora Cañada1, Antonio Ruiz Medina, Johannes Frank, Bernhard Lendl.   

Abstract

The technique of bead injection has been adapted for surface enhanced Raman scattering (SERS) to substantially improve precision, long term stability and sensitivity of SERS detection in analytical chemistry. For this purpose a fully automated flow system comprising a dedicated flow-cell has been developed and tested. With the developed flow-cell, which contains two inlet and two outlet channels, it is possible to retain, perfuse and discharge minute amounts of polymer beads while monitoring all steps by Raman spectroscopy. First, beads carrying cation exchanger moieties were retained in the flow-cell and subsequently perfused with a silver nitrate and a hydroxylamine solution using one inlet of the flow cell. By this sequence homogeneous SERS active silver layers were formed on the beads. The uniformity of the achieved silver layer was studied by secondary electron microscopy. For measurement, the analyte was then introduced from the second inlet channel such that the interaction between the activated SERS beads and analyte occurred in close proximity and within the focus of the laser excitation beam. Due to the complete computer control of all experimental steps, including bead entrapment, SERS layer generation, sample introduction and final bead removal, highly reproducible conditions for SERS were achieved. The method was developed using 9-aminoacridine as a test molecule. Quantitative studies were carried out for 9-aminoacridine and acridine showing linear calibrations from 1-100 nmol l(-1) and 50-1,000 nmol l(-1), respectively, using a sample volume of 200 microl each. Typical relative standard deviations were 4.7% for 9-aminoacrine and 5.8% for acridine.

Entities:  

Year:  2002        PMID: 12430611     DOI: 10.1039/b204073e

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  1 in total

1.  Microfluidic setup for on-line SERS monitoring using laser induced nanoparticle spots as SERS active substrate.

Authors:  Oana-M Buja; Ovidiu D Gordan; Nicolae Leopold; Andreas Morschhauser; Jörg Nestler; Dietrich R T Zahn
Journal:  Beilstein J Nanotechnol       Date:  2017-01-24       Impact factor: 3.649

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.