Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water.

G Bedogni1, M Malavolti, S Severi, M Poli, C Mussi, A L Fantuzzi, N Battistini.   

Abstract

OBJECTIVE: To establish the accuracy of an eight-polar tactile-electrode impedance method in the assessment of total body water (TBW).
DESIGN: Transversal study.
SETTING: University department.
SUBJECTS: Fifty healthy subjects (25 men and 25 women) with a mean (s.d.) age of 40 (12) y.
METHODS: TBW measured by deuterium oxide dilution; resistance (R) of arms, trunk and legs measured at frequencies of 5, 50, 250 and 500 kHz with an eight-polar tactile-electrode impedance-meter (InBody 3.0, Biospace, Seoul, Korea).
RESULTS: An algorithm for the prediction of TBW from the whole-body resistance index at 500 kHz (height (2)/R(500) where R is the sum of the segmental resistances of arms, trunk and legs) was developed in a randomly chosen subsample of 35 subjects. This algorithm had an adjusted coefficient of determination (r2(adj)) of 0.81 (P<0.0001) and a root mean square error (RMSE) of 3.6 l (9%). Cross-validation of the predictive algorithm in the remaining 15 subjects gave an r2(adj) of 0.87 (P<0.0001) and an RMSE of 3.0 l (8%). The precision of eight-polar BIA, determined by measuring R three times a day for five consecutive days in a fasting subject, was < or =2.8% for all segments and frequencies.
CONCLUSION: Eight-polar BIA is a precise method that offers accurate estimates of TBW in healthy subjects. This promising method should undergo further studies of precision and its accuracy in assessing extracellular water and appendicular body composition should be determined. SPONSORSHIP: Modena and Reggio Emilia University.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12428182     DOI: 10.1038/sj.ejcn.1601466

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


  47 in total

1.  Association of milk consumption frequency on muscle mass and strength: an analysis of three representative Korean population studies.

Authors:  Yu-Jin Kwon; Ji-Won Lee; Jun-Hyuk Lee; Hye Sun Lee; Hyungmi Kim
Journal:  Eur J Nutr       Date:  2019-12-19       Impact factor: 5.614

2.  How Length Sizes Affect Body Composition Estimation in Adolescent Athletes Using Bioelectrical Impedance.

Authors:  Katinka Utczás; Zsófia Tróznai; Gergely Pálinkás; Irina Kalabiska; Leonidas Petridis
Journal:  J Sports Sci Med       Date:  2020-08-13       Impact factor: 2.988

3.  Antioxidant activity of the new black vinegar "IZUMI".

Authors:  M Nagashima; K Saito
Journal:  J Nutr Health Aging       Date:  2010-12       Impact factor: 4.075

4.  Bioimpedance Guided Fluid Management in Peritoneal Dialysis: A Randomized Controlled Trial.

Authors:  Na Tian; Xiao Yang; Qunying Guo; Qian Zhou; Chunyan Yi; Jianxiong Lin; Peiyi Cao; Hongjian Ye; Menghua Chen; Xueqing Yu
Journal:  Clin J Am Soc Nephrol       Date:  2020-05-07       Impact factor: 8.237

5.  Bioelectrical Impedance Analysis for the Assessment of Sarcopenia in Patients with Cancer: A Systematic Review.

Authors:  Gabriel F P Aleixo; Shlomit S Shachar; Kirsten A Nyrop; Hyman B Muss; Claudio L Battaglini; Grant R Williams
Journal:  Oncologist       Date:  2019-11-12

6.  Impact of childhood obesity treatment on body composition and metabolic profile.

Authors:  Marja Kalavainen; Pauliina Utriainen; Esko Vanninen; Matti Korppi; Outi Nuutinen
Journal:  World J Pediatr       Date:  2011-11-21       Impact factor: 2.764

7.  High relative fat-free mass is important for maintaining serum albumin levels in patients with compensated liver cirrhosis.

Authors:  Kazuhiro Kotoh; Makoto Nakamuta; Marie Fukushima; Chitose Matsuzaki; Munechika Enjoji; Hironori Sakai; Hajime Nawata
Journal:  World J Gastroenterol       Date:  2005-03-07       Impact factor: 5.742

8.  Exploration of Fluid Dynamics in Perioperative Patients Using Bioimpedance Analysis.

Authors:  Jae Uk Chong; Sangguen Nam; Hee Jung Kim; Rami Lee; Yunjung Choi; Jae Gil Lee; Kyung Sik Kim
Journal:  J Gastrointest Surg       Date:  2015-12-29       Impact factor: 3.452

9.  Extracellular volume expansion and the preservation of residual renal function in Korean peritoneal dialysis patients: a long-term follow up study.

Authors:  Harin Rhee; Min Ja Baek; Hyun Chul Chung; Jong Man Park; Woo Jin Jung; Soo Min Park; Jang Won Lee; Min Ji Shin; Il Young Kim; Sang Heon Song; Dong Won Lee; Soo Bong Lee; Ihm Soo Kwak; Eun Young Seong
Journal:  Clin Exp Nephrol       Date:  2015-11-26       Impact factor: 2.801

10.  Assessment of fluid shifts of body compartments using both bioimpedance analysis and blood volume monitoring.

Authors:  Soo-Jeong Yu; Do-Hyoung Kim; Dong-Jin Oh; Suk-Hee Yu; Eung-Tack Kang
Journal:  J Korean Med Sci       Date:  2006-02       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.