Literature DB >> 12427353

Permeability of medical gloves to mono- and dimethacrylate monomers in dental restorative materials.

Emma-Christin Lönnroth1, I Eystein Ruyter.   

Abstract

Dental personnel manually handle methacrylate-based restorative materials, which can cause skin irritation and allergies. The protection given by different types of medical gloves is not well known. Breakthrough time (BTT, min) was used as a measure of protection according to a European standard, using 2 test mixtures consisting of respectively 3 and 5 monomers. Fourteen gloves representing natural rubber latex, synthetic rubber, and synthetic polymeric material were tested. The BTT ranged from some minutes to more than 2 hrs for the 4 monomers with a molecular mass less than 300. The longest protection was recorded for Nitra Touch (nitrile rubber), Tactylon (synthetic rubber), and Metin (PVC).

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12427353     DOI: 10.1080/10803548.2002.11076540

Source DB:  PubMed          Journal:  Int J Occup Saf Ergon        ISSN: 1080-3548


  2 in total

Review 1.  World at work: Dental laboratory technicians.

Authors:  N Torbica; S Krstev
Journal:  Occup Environ Med       Date:  2006-02       Impact factor: 4.402

Review 2.  Glove permeation of chemicals: The state of the art of current practice-Part 2. Research emphases on high boiling point compounds and simulating the donned glove environment.

Authors:  Sean Banaee; Shane S Que Hee
Journal:  J Occup Environ Hyg       Date:  2020-03-25       Impact factor: 2.155

  2 in total