Literature DB >> 12424601

Management of chronic postoperative pain following incisional hernia repair with Composix mesh: a report of two cases.

K A LeBlanc1, J M Whitaker.   

Abstract

There are new prosthetic biomaterials that are used to repair various defects in the abdominal wall. These have been developed within the last several years. The results of many of these products are not yet available. We report on two patients who developed chronic-pain syndromes that could only be related to the use of Composix mesh. This entity may become more conspicuous in the future, thereby presenting the surgeon with difficulty in approaching this new and difficult problem. We believe that shrinkage of the prosthesis was responsible for the pain. Both of these patients responded favorably to resection of the mesh by the open or laparoscopic technique. This was followed by repair of the fascial defect with DualMesh by the open or laparoscopic method. We were successful in the achievement of the relief of the pain and the repair of the hernia in both cases. We believe that this entity can be treated successfully by this approach. The laparoscopic method is favored.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12424601     DOI: 10.1007/s10029-002-0075-z

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  15 in total

1.  Initial experience of double-layer tension free reconstruction of abdominal wall defects with porcine acellular dermal collagen implant and polypropylene mesh.

Authors:  F M Shaikh; T E Kennedy; E G Kavanagh; P A Grace
Journal:  Ir J Med Sci       Date:  2011-10-27       Impact factor: 1.568

Review 2.  Incisional hernia: open techniques.

Authors:  Uwe Klinge; Joachim Conze; Carsten J Krones; Volker Schumpelick
Journal:  World J Surg       Date:  2005-08       Impact factor: 3.352

3.  Incisional hernia: challenge of re-operations after mesh repair.

Authors:  Joachim Conze; Carsten J Krones; Volker Schumpelick; Uwe Klinge
Journal:  Langenbecks Arch Surg       Date:  2006-09-02       Impact factor: 3.445

4.  Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model.

Authors:  Maja L Konstantinovic; Eline Pille; Marta Malinowska; Eric Verbeken; Dirk De Ridder; Jan Deprest
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-10-10

5.  Lessons and challenges during a 5-year follow-up of 21 Composix Kugel implantations.

Authors:  A Wiegering; N Schlegel; C Isbert; C Jurowich; S Doht; C T Germer; U A Dietz
Journal:  Hernia       Date:  2013-05-09       Impact factor: 4.739

6.  Laparoscopic versus open hernia repair: outcomes and sociodemographic utilization results from the nationwide inpatient sample.

Authors:  Paul D Colavita; Victor B Tsirline; Amanda L Walters; Amy E Lincourt; Igor Belyansky; B Todd Heniford
Journal:  Surg Endosc       Date:  2012-06-26       Impact factor: 4.584

Review 7.  Laparoscopic ventral hernia repair with the Goretex Dualmesh: long-term results and review of the literature.

Authors:  Ph Topart; L Ferrand; F Vandenbroucke; P Lozac'h
Journal:  Hernia       Date:  2005-07-13       Impact factor: 4.739

8.  Fibrin glue for intraperitoneal laparoscopic mesh fixation: a comparative study in a swine model.

Authors:  Tatyan Clarke; Namir Katkhouda; Rodney J Mason; Bon C Cheng; Jeffrey Algra; Jaisa Olasky; Helen J Sohn; Ashkan Moazzez; Maryam Balouch
Journal:  Surg Endosc       Date:  2010-07-31       Impact factor: 4.584

9.  Surgical treatment of large incisional hernias with an intraperitoneal Parietex Composite mesh: our preliminary experience on 26 cases.

Authors:  C Ammaturo; G Bassi
Journal:  Hernia       Date:  2004-05-14       Impact factor: 4.739

10.  Multicentric observational cohort study evaluating a composite mesh with incorporated oxidized regenerated cellulose in laparoscopic ventral hernia repair.

Authors:  F Berrevoet; K Fierens; J De Gols; B Navez; W Van Bastelaere; E Meir; R Ceulemans
Journal:  Hernia       Date:  2008-08-06       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.