Literature DB >> 12424484

Exhaled nitric oxide collected with two different mouthpieces: a study in asthmatic patients.

A S Leme1, D I Kasahara, M P T Nunes, M A Martins, J E Vieira.   

Abstract

Techniques for collecting exhaled nitric oxide (ENO) recommend the use of antibacterial filters of 0.3 m. The aim of the present study was to compare the measurements of ENO obtained with two different filtering devices. Air samples from 17 asthmatic and 17 non-asthmatic subjects were collected by a recommended off-line technique using two different mouthpieces: 1) the Sievers disposable tool (A) under a breathing pressure of 18 cmH2O, and 2) a mouthpiece containing a HEPA filter (B) under a breathing pressure of 12 cmH2O. The nitric oxide samples were collected into an impermeable reservoir bag. Values for ENO were compared using two-way repeated measures ANOVA followed by the Tukey test. Agreement was assessed by Bland-Altman analysis. ENO values obtained with mouthpieces A and B were comparable for asthmatic (mean +/- SEM, 42.9 +/- 6.9 vs 43.3 +/- 6.6 ppb) and non-asthmatic (13.3 +/- 1.3 vs 13.7 +/- 1.1 ppb) subjects. There was a significant difference in ENO between asthmatics and non-asthmatics using either mouthpiece A (P<0.001) or B (P<0.001). There was a positive correlation between mouthpiece A and mouthpiece B for both groups. The Bland-Altman limits of agreement were considered to be acceptable. Mouthpiece B was less expensive than A, and these data show that it can be used without compromising the result. Our data confirm reports of higher ENO values in the presence of airway inflammation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12424484     DOI: 10.1590/s0100-879x2002001000004

Source DB:  PubMed          Journal:  Braz J Med Biol Res        ISSN: 0100-879X            Impact factor:   2.590


  3 in total

1.  Outdoor Endurance Training with Air Pollutant Exposure Versus Sedentary Lifestyle: A Comparison of Airway Immune Responses.

Authors:  Juliana de Melo Batista Dos Santos; Roberta Foster; Anne-Charlotte Jonckheere; Marcelo Rossi; Luiz Antonio Luna Junior; Catherine Machado Katekaru; Matheus Cavalcante de Sá; Lucas Guimarães Pagani; Francine Maria de Almeida; Jônatas do Bussador Amaral; Rodolfo de Paula Vieira; Andre Luis Lacerda Bachi; Dominique Magdalena A Bullens; Mauro Vaisberg
Journal:  Int J Environ Res Public Health       Date:  2019-11-12       Impact factor: 3.390

2.  Analysis of the sputum and inflammatory alterations of the airways in patients with common variable immunodeficiency and bronchiectasis.

Authors:  Andrea Cristina Pereira; Cristina M Kokron; Beatriz Mangueira Saraiva Romagnolo; Claudia Simeire Albertini Yagi; Paulo Hilário Nascimento Saldiva; Geraldo Lorenzi Filho; Elnara Marcia Negri
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

3.  Non-asthmatic patients show increased exhaled nitric oxide concentrations.

Authors:  Beatriz M Saraiva-Romanholo; Fabio S Machado; Francine M Almeida; Maria do Patrocínio T Nunes; Milton A Martins; Joaquim E Vieira
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.