Improvement of three-dimensional treatment planning models of small lung targets using high-speed multi-slice computed tomographic imaging.

Kazunari Yamada1, Toshinori Soejima, Eisaku Yoden, Tsutomu Maruta, Takanobu Okayama, Kazuro Sugimura.   

Abstract

PURPOSE: To improve the reliability of the patient model and reduce treatment volume by acquiring multi-slice computed tomographic (CT) data with the patients' single holding of breath at normal inhalation and exhalation. METHODS AND MATERIALS: Seven patients with nine small peripheral lung cancer tumors underwent CT scanning under three respiration conditions using multi-slice CT: free breathing (FB), shallow inspiration (SI), and shallow expiration (SE). To compare the treatment plan created using the two-respiratory-phase images (SI + SE) with the plans created using only SE images or using only FB images, we attempted to calculate the true dosimetric characteristics for three-dimensional treatment planning taking respiratory movement into consideration. Minimum dose to the gross tumor volume (GTV) and ipsilateral lung dose-volume histogram (DVH) were calculated for the inhalation and exhalation positions of shallow breathing.
RESULTS: There was no significant difference between minimum doses of the GTV in the three treatment plans when using anteroposterior/posteroanterior parallel-opposed fields. However, there was a significant difference between the minimum doses of the GTV in the two-phase treatment plan and the minimum dose in the other treatment plans when using the four-field technique, consisting of shaped anterior, posterior, right and left lateral fields (p = 0.03, 0.04). Comparison of the percent volume of ipsilateral lung receiving a dose exceeding 20 Gy (V(20)) based on inhalation and exhalation CT data revealed that the V(20) of the two-phase plan was the smallest of the three treatment planning fields (p < 0.001).
CONCLUSION: Two-phase planning using multi-slice CT provides an immediate reduction in the amount of normal tissue treated and improved reliability of patient data for DVH modeling.

Entities:  

Mesh:

Year:  2002        PMID: 12419450     DOI: 10.1016/s0360-3016(02)03813-0

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  To study tumor motion and planning target volume margins using four dimensional computed tomography for cancer of the thorax and abdomen regions.

Authors:  Sudesh Deshpande
Journal:  J Med Phys       Date:  2011-01

2.  Definition of internal target volumes based on planar X-ray fluoroscopic images for lung and hepatic stereotactic body radiation therapy. Comparison to inhale/exhale CT technique.

Authors:  David Sevillano; Luis Miguel Núñez; Margarita Chevalier; Feliciano García-Vicente
Journal:  J Appl Clin Med Phys       Date:  2020-05-30       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.