Literature DB >> 12418763

Preferential use of sonographically guided biopsy to minimize patient discomfort and procedure time in a percutaneous image-guided breast biopsy program.

Martha B Mainiero1, Ilana F Gareen, Chloe E Bird, Wendy Smith, Cynthia Cobb, Barbara Schepps.   

Abstract

OBJECTIVE: To determine whether preferential use of sonographic guidance for percutaneous biopsy of breast masses results in a subset of patients with a shorter procedure time and less discomfort compared with patients undergoing stereotactic biopsy.
METHODS: A prospective observational study was performed on 193 women undergoing percutaneous image-guided breast biopsy between 1997 and 1999. Data were collected on room time, physician time, and patient comfort levels for 122 stereotactic and 71 sonographically guided biopsies. Differences between stereotactic and sonographically guided biopsy for all lesions and for masses were analyzed for statistical significance.
RESULTS: Mean room times were 62.2 minutes for stereotactic biopsy and 39.4 minutes for sonographically guided biopsy (P < .0001). Mean physician times were 23.0 minutes for stereotactic biopsy and 15.8 minutes for sonographically guided biopsy (P < .0001). When we limited our analyses to women undergoing biopsy for masses, the difference in physician time largely disappeared, but the difference in room time remained (P < .0001). Women undergoing stereotactic biopsy were more likely to report discomfort due to body positioning than were women undergoing sonographically guided biopsy (P < .001). These differences existed whether we included all lesions or restricted our analyses to masses.
CONCLUSIONS: Preferential use of sonographically guided breast biopsy for masses results in shorter procedure times and less patient discomfort compared with prone stereotactic biopsy.

Entities:  

Mesh:

Year:  2002        PMID: 12418763     DOI: 10.7863/jum.2002.21.11.1221

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  11 in total

Review 1.  Accuracy of ultrasound-guided, large-core needle breast biopsy.

Authors:  G Schueller; C Schueller-Weidekamm; T H Helbich
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

2.  Factors associated with upstaging of ductal carcinoma in situ diagnosed by core needle biopsy using imaging guidance.

Authors:  Cholatip Wiratkapun; Pachara Patanajareet; Bussanee Wibulpholprasert; Panuwat Lertsithichai
Journal:  Jpn J Radiol       Date:  2011-09-17       Impact factor: 2.374

3.  An evaluation of patient experience during percutaneous breast biopsy.

Authors:  Jean M Seely; Fraser Hill; Susan Peddle; Jackie Lau
Journal:  Eur Radiol       Date:  2017-05-22       Impact factor: 5.315

4.  The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases.

Authors:  Mary F Dillon; Arnold D K Hill; Cecily M Quinn; Ann O'Doherty; Enda W McDermott; Niall O'Higgins
Journal:  Ann Surg       Date:  2005-11       Impact factor: 12.969

5.  Breast cancer detection with short-interval follow-up compared with return to annual screening in patients with benign stereotactic or US-guided breast biopsy results.

Authors:  Jason M Johnson; Alisa K Johnson; Ellen S O'Meara; Diana L Miglioretti; Berta M Geller; Elise N Hotaling; Sally D Herschorn
Journal:  Radiology       Date:  2014-11-25       Impact factor: 11.105

6.  Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

Authors:  Yao-Lung Kuo; Tsai-Wang Chang
Journal:  BMC Cancer       Date:  2010-07-16       Impact factor: 4.430

7.  False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies.

Authors:  Marek Boba; Urszula Kołtun; Barbara Bobek-Billewicz; Ewa Chmielik; Bartosz Eksner; Tomasz Olejnik
Journal:  Pol J Radiol       Date:  2011-01

8.  Preoperatively diagnosed ductal cancers in situ of the breast presenting as even small masses are of high risk for the invasive cancer foci in postoperative specimen.

Authors:  Bartlomiej Szynglarewicz; Piotr Kasprzak; Agnieszka Halon; Rafal Matkowski
Journal:  World J Surg Oncol       Date:  2015-07-16       Impact factor: 2.754

9.  The negative predictive value of ultrasound-guided 14-gauge core needle biopsy of breast masses: a validation study of 339 cases.

Authors:  Charlie Zhang; Darrell R Lewis; Paola Nasute; Malcolm Hayes; Linda J Warren; Paula B Gordon
Journal:  Cancer Imaging       Date:  2012-10-31       Impact factor: 3.909

10.  Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure.

Authors:  Judith M Hemmer; Johannes C Kelder; Hans P M van Heesewijk
Journal:  Eur Radiol       Date:  2007-10-02       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.