Literature DB >> 12418653

Use of a chemical sensor array for detecting pollutants in domestic wastewater.

W Bourgeois1, R M Stuetz.   

Abstract

A chemical sensor array (consisting of 8 conducting polymers) was used to continuously monitor for the presence or absence of industrial pollutants in the headspace of wastewater generated from an on-line flow-cell. A domestic wastewater (Cranfield University sewage works) was dosed with diesel to stimulate the presence of an intermittent discharge in a wastewater influent. Response patterns between the sensors were used to detect for the presence of organic compounds in the wastewater. Correlations between the sensor response patterns or fingerprints were also analysed using principal component analysis. The results clearly demonstrate that a chemical sensor array can rapidly identify the presence of organic compounds (such as diesel) in a wastewater matrix and could be further developed to monitor for industrial pollutants at the inlet of a sewage works.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12418653     DOI: 10.1016/s0043-1354(02)00183-5

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  6 in total

Review 1.  Diverse applications of electronic-nose technologies in agriculture and forestry.

Authors:  Alphus D Wilson
Journal:  Sensors (Basel)       Date:  2013-02-08       Impact factor: 3.576

2.  Structure and sensor properties of thin ordered solid films.

Authors:  Jadwiga Sołoducho; Joanna Cabaj; Agnieszka Swist
Journal:  Sensors (Basel)       Date:  2009-09-28       Impact factor: 3.576

3.  Application of gas sensor arrays in assessment of wastewater purification effects.

Authors:  Łukasz Guz; Grzegorz Łagód; Katarzyna Jaromin-Gleń; Zbigniew Suchorab; Henryk Sobczuk; Andrzej Bieganowski
Journal:  Sensors (Basel)       Date:  2014-12-23       Impact factor: 3.576

4.  Evaluation of Hydrocarbon Soil Pollution Using E-Nose.

Authors:  Andrzej Bieganowski; Grzegorz Józefaciuk; Lidia Bandura; Łukasz Guz; Grzegorz Łagód; Wojciech Franus
Journal:  Sensors (Basel)       Date:  2018-07-30       Impact factor: 3.576

5.  Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants.

Authors:  Jacek Gebicki; Hubert Byliński; Jacek Namieśnik
Journal:  Environ Monit Assess       Date:  2015-12-15       Impact factor: 2.513

6.  Polyelectrolyte Based Sensors as Key to Achieve Quantitative Electronic Tongues: Detection of Triclosan on Aqueous Environmental Matrices.

Authors:  Cátia Magro; Paulo Zagalo; João Pereira-da-Silva; Eduardo Pires Mateus; Alexandra Branco Ribeiro; Paulo Ribeiro; Maria Raposo
Journal:  Nanomaterials (Basel)       Date:  2020-03-29       Impact factor: 5.076

  6 in total