Literature DB >> 12418016

Mechanical properties of coagulated albumin and failure mechanisms of liver repaired with the use of an argon-beam coagulator with albumin.

T P Moffitt1, D A Baker, S J Kirkpatrick, S A Prahl.   

Abstract

Hemostasis in the traumatized liver has been achieved by thermally denaturing topically applied albumin. In this article, the mechanical properties of liver and denatured albumin (solder) were measured, and the failure methods of liver repaired with albumin were identified. The ultimate tensile strength and Young's modulus were measured for healthy liver (N = 20) and thermally damaged liver (N = 20). The ultimate tensile strength and Young's modulus were measured for three concentrations of coagulated albumin (25, 38, and 53%) in a single layer and for two layers of denatured 38% albumin. Failure under tension of argon-beam coagulator soldered liver on the parenchymal surface (N = 30) with 38% albumin in two layers had a 70% occurrence for tearing at a mean stress of 39 kPa and a 23% occurrence for shearing at a mean stress of 7 kPa. Liver repaired on the interior surface (N = 11) failed in tension by tearing (64%) at a mean stress of 34 kPa and by shearing (36%) at a mean stress of 6 kPa. Argon-beam coagulator soldering with 38% albumin took 6 s/cm(2) for two layers of solder and gave the best balance of usability, strength, and matching of mechanical properties with those of the liver. Copyright 2002 Wiley Periodicals, Inc.

Mesh:

Substances:

Year:  2002        PMID: 12418016     DOI: 10.1002/jbm.10389

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  6 in total

1.  Multi-scale model for investigating the electrical properties and mechanical properties of liver tissue undergoing ablation.

Authors:  Wei-Hsuan Huang; Chee-Kong Chui; Etsuko Kobayashi; Swee-Hin Teoh; Stephen Chang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-12-16       Impact factor: 2.924

2.  Viscoelastic characterization of in vitro canine tissue.

Authors:  Miklos Z Kiss; Tomy Varghese; Timothy J Hall
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

3.  Biomedical electrosurgery devices containing nanostructure for minimally invasive surgery: reduction of thermal injury and acceleration of wound healing for liver cancer.

Authors:  Wen-Tien Hsiao; Li-Hsiang Lin; Hsi-Jen Chiang; Keng-Liang Ou; Han-Yi Cheng
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

4.  Effects of tissue mechanical properties on susceptibility to histotripsy-induced tissue damage.

Authors:  Eli Vlaisavljevich; Yohan Kim; Gabe Owens; William Roberts; Charles Cain; Zhen Xu
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

5.  Hemostasis after liver resection improves after single application of albumin and argon beam coagulation.

Authors:  Genevieve R Mueller; Ronald F Wolf; Paul D Hansen; Kenton W Gregory; Scott A Prahl
Journal:  J Gastrointest Surg       Date:  2010-07-07       Impact factor: 3.452

6.  Investigation of temperature-dependent viscoelastic properties of thermal lesions in ex vivo animal liver tissue.

Authors:  Miklos Z Kiss; Matthew J Daniels; Tomy Varghese
Journal:  J Biomech       Date:  2009-04-10       Impact factor: 2.712

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.