Literature DB >> 12417992

Inductively coupled stent antennas in MRI.

Harald H Quick1, Hilmar Kuehl, Gernot Kaiser, Silke Bosk, Jörg F Debatin, Mark E Ladd.   

Abstract

The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long-term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessment of the vascular system. However, a detailed assessment of the stent lumen with MRI is often hampered by material-dependent susceptibility artifacts, as well as by radiofrequency (RF) eddy currents generated inside the electrically conducting stent mesh. In this study, stent prototypes were designed to act as active resonant structures at the Larmor frequency of the MR system. Employing the principle of inductive coupling, the B(1) fields of the stents were coupled to that of an outside surface coil. The stents thus acted as local RF signal amplifiers. Various stent designs were investigated regarding their coupling to an external coil, signal homogeneity, and suitability for mechanical expansion for implantation purposes. The dependency of flip angle amplification on the quality factor Q of the stents was systematically investigated. Phantom experiments revealed signal amplification in all stent prototypes. Signal enhancement inside and close to the surface of the stents enabled their localization with high contrast in MR images. In vivo imaging experiments in the iliac, renal, and splenic arteries of two pigs confirmed the in vitro findings. Wireless active visualization of stents allows for detailed analysis of the stent lumen with high contrast and spatial resolution. The proposed method could thus provide a powerful diagnostic means for the noninvasive long-term follow-up of stent patency, thereby enhancing our understanding of the mechanisms of restenosis. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12417992     DOI: 10.1002/mrm.10269

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Sensitivity enhancement of remotely coupled NMR detectors using wirelessly powered parametric amplification.

Authors:  Chunqi Qian; Joseph Murphy-Boesch; Stephen Dodd; Alan Koretsky
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

Review 2.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

3.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

Review 4.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

Review 5.  Advances in interventional cardiovascular MRI.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

Review 6.  Interventional cardiovascular magnetic resonance imaging.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Trends Cardiovasc Med       Date:  2007-08       Impact factor: 6.677

7.  Using a low-amplitude RF pulse at echo time (LARFET) for device localization in MRI.

Authors:  Murat Tümer; Baykal Sarioglu; Senol Mutlu; Yekta Ulgen; Arda Yalcinkaya; Cengizhan Ozturk
Journal:  Med Biol Eng Comput       Date:  2014-08-31       Impact factor: 2.602

Review 8.  Engineering novel detectors and sensors for MRI.

Authors:  Chunqi Qian; Gary Zabow; Alan Koretsky
Journal:  J Magn Reson       Date:  2012-11-29       Impact factor: 2.229

Review 9.  An overview on the advances in cardiovascular interventional MR imaging.

Authors:  Olaf Saborowski; Maythem Saeed
Journal:  MAGMA       Date:  2007-05-09       Impact factor: 2.310

Review 10.  Cardiovascular magnetic resonance guided electrophysiology studies.

Authors:  Aravindan Kolandaivelu; Albert C Lardo; Henry R Halperin
Journal:  J Cardiovasc Magn Reson       Date:  2009-07-06       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.