Y Liu1, E B Hunziker, N X Randall, K de Groot, P Layrolle.
Abstract
In a previous investigation, we demonstrated that when bovine serum albumin (BSA) is biomimetically co-precipitated with Ca(2+) and PO(4)(3-) ions upon titanium-alloy implants, it becomes incorporated into the crystal lattice and is not merely deposited on its surface. Moreover, the protein elicited a change in crystal structure from an octacalcium phosphate type to a carbonated apatite one, which bears a closer resemblance to natural bone mineral. In the present study, we investigated the dissolution rate and mechanical strength of such BSA-containing coatings as a function of protein concentration within the bathing medium (10 ng/ml to 1.0 mg/ml). BSA-containing coatings released Ca(2+) ions more slowly (5 ppm/min) than did non-BSA-containing ones (10 ppm/min), but this rate did not change as a function of protein concentration within the bathing medium. In contrast, the strength of coatings increased almost linearly as a function of protein concentration within the bathing medium, indicating that BSA incorporated into the crystal lattice enhances its mechanical strength in a concentration-dependent manner. Copyright 2002 Elsevier Science Ltd.Entities:
Mesh:
Substances:
Year: 2003 PMID: 12417179 DOI: 10.1016/s0142-9612(02)00252-1