Literature DB >> 12407378

An external, oversized, porous polyester stent reduces vein graft neointima formation, cholesterol concentration, and vascular cell adhesion molecule 1 expression in cholesterol-fed pigs.

Gianni D Angelini1, Clinton Lloyd, Ray Bush, Jason Johnson, Andrew C Newby.   

Abstract

BACKGROUND: Reducing neointima formation and atherosclerosis are key goals in preventing late vein graft failure. Although pharmacologic and mechanical solutions have been proposed, the demonstration that these influence both aspects of vein graft pathology have been lacking. Supporting grafts externally with an oversized, highly porous polyester stent dramatically reduces neointima formation in normocholesterolemic pigs. However, its effects in the presence of hypercholesterolemia are unknown.
METHODS: We compared wall thickening, cholesterol concentration, foam-cell formation, and the expression of the leukocyte adhesion molecule vascular cell adhesion molecule 1 after 3 months in stented and unstented saphenous vein interposition grafts into the carotid arteries of pigs fed cholesterol to cause modest hypercholesterolemia (11.2 +/- 1.2 mmol/L).
RESULTS: Stenting reduced neointima formation from 5.6 +/- 0.4 to 1.2 +/- 0.2 mm(2) (n = 7; P <.00002, paired t test) and graft cholesterol concentration from 4.7 +/- 1.2 to 2.1 +/- 1.3 mg/g wet weight (P <.02). Foam cells were observed in unstented grafts (mean, 1.5% +/- 0.5% of all cells) but never in stented grafts. Vascular cell adhesion molecule 1 was strongly expressed in 53% +/- 8% of intimal and medial cells in unstented grafts but was weakly expressed in only 19% +/- 3% (n = 4, P <.05) of stented grafts.
CONCLUSIONS: We conclude that external stenting with polyester favorably influences both neointima formation and early atherosclerosis, both of which are key aspects of vein graft disease, and that decreased expression of vascular cell adhesion molecule 1 is part of the underlying mechanism.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12407378     DOI: 10.1067/mtc.2002.127004

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  15 in total

1.  Why are the intramyocardial portions of the coronary arteries spared from arteriosclerosis? Clinical implications.

Authors:  Donald M Botta; John A Elefteriades
Journal:  Int J Angiol       Date:  2009

2.  Short-term effects of double-layer autologous vein graft on restraint of excessive distension and alleviation of neointimal hyperplasia in a porcine saphenous vein graft model.

Authors:  Qiang Ji; Yunqing Mei; Xisheng Wang; Jing Feng; Jianzhi Cai; Yifeng Sun; Wusha Dewei; Chunping Wang; Liangjie Chi
Journal:  Heart Vessels       Date:  2010-12-25       Impact factor: 2.037

3.  Functional remodeling of an electrospun polydimethylsiloxane-based polyether urethane external vein graft support device in an ovine model.

Authors:  Mohammed El-Kurdi; Lorenzo Soletti; Jonathan McGrath; Stephen Linhares; Serge Rousselle; Howard Greisler; Elazer Edelman; Frederick J Schoen
Journal:  J Biomed Mater Res A       Date:  2019-05-27       Impact factor: 4.396

Review 4.  Mechanisms of vein graft adaptation to the arterial circulation: insights into the neointimal algorithm and management strategies.

Authors:  Akihito Muto; Lynn Model; Kenneth Ziegler; Sammy D D Eghbalieh; Alan Dardik
Journal:  Circ J       Date:  2010-07-01       Impact factor: 2.993

Review 5.  Vein graft failure: from pathophysiology to clinical outcomes.

Authors:  Margreet R de Vries; Karin H Simons; J Wouter Jukema; Jerry Braun; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2016-05-19       Impact factor: 32.419

Review 6.  Biomaterial-Based Approaches to Address Vein Graft and Hemodialysis Access Failures.

Authors:  Timothy C Boire; Daniel A Balikov; Yunki Lee; Christy M Guth; Joyce Cheung-Flynn; Hak-Joon Sung
Journal:  Macromol Rapid Commun       Date:  2016-09-27       Impact factor: 5.734

7.  Extravascular perivenous fibrin support leads to aneurysmal degeneration and intimal hyperplasia in arterialized vein grafts in the rat.

Authors:  Tomislav Stojanovic; Ali El-Sayed Ahmad; Vasilios Didilis; Osama Ali; Aron F Popov; Bernd C Danner; Ralf Seipelt; Hilmar Dörge; Friedrich A Schöndube
Journal:  Langenbecks Arch Surg       Date:  2008-05-29       Impact factor: 3.445

8.  Oversized vein grafts develop advanced atherosclerosis in hypercholesterolemic minipigs.

Authors:  Troels Thim; Mette Kallestrup Hagensen; Arne Hørlyck; Ludovic Drouet; William P Paaske; Hans Erik Bøtker; Erling Falk
Journal:  BMC Cardiovasc Disord       Date:  2012-03-31       Impact factor: 2.298

9.  Effects of the different-sized external stents on vein graft intimal hyperplasia and inflammation.

Authors:  Qi Yang; Dong Lei; Shixing Huang; Yi Yang; Yang Yang; Xiaofeng Ye; Zhengwei You; Qiang Zhao
Journal:  Ann Transl Med       Date:  2020-02

10.  Expandable external support device to improve Saphenous Vein Graft Patency after CABG.

Authors:  Yanai Ben-Gal; David P Taggart; Mathew R Williams; Eyal Orion; Gideon Uretzky; Rona Shofti; Shmuel Banai; Liad Yosef; Gil Bolotin
Journal:  J Cardiothorac Surg       Date:  2013-05-06       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.