Literature DB >> 12403661

Reproducibility of chronic infarct size measurement by contrast-enhanced magnetic resonance imaging.

Heiko Mahrholdt1, Anja Wagner, Thomas A Holly, Michael D Elliott, Robert O Bonow, Raymond J Kim, Robert M Judd.   

Abstract

BACKGROUND: The reproducibility of contrast-enhanced MRI has not been established. We compared MRI reproducibility for infarct size determination with that of (99m)Tc-sestamibi (MIBI) single photon emission computed tomography (SPECT). METHODS AND
RESULTS: Patients with chronic myocardial infarction defined by enzymes (peak creatine kinase-MB 173+/-119 U/L) were scanned twice by MRI (MRI I and MRI II, n=20) and twice by SPECT (SPECT I and SPECT II, n=15) on the same day. The MRI contrast agent was injected during MRI I but not MRI II to test the effect of imaging time after contrast. Resting Tc-MIBI SPECT images were acquired and infarct size was determined with commercial software. Infarct size in patients scanned by MRI and SPECT was 14+/-6% of left ventricular mass (%LV) by MRI (range 4%LV to 27%LV) and 14+/-7%LV by SPECT (range 4%LV to 26%LV). MRI I and II scans were performed 10+/-2 and 27+/-3 minutes after contrast, respectively. For MRI, the difference in infarct size between scans I and II (bias) was -0.1%LV, and the coefficient of repeatability was +/-2.4%LV. For SPECT, bias was -1.3%LV, and the coefficient of repeatability was +/-4.0%LV. Within individual patients, no systematic differences in infarct size were detected when the 2 MRI scans were compared, the 2 SPECT scans were compared, or MRI was compared to SPECT.
CONCLUSION: The size of healed infarcts measured by contrast-enhanced MRI does not change between 10 and 30 minutes after contrast. The clinical reproducibility of contrast-enhanced MRI for infarct size determination compares favorably with that of routine clinical SPECT.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12403661     DOI: 10.1161/01.cir.0000036368.63317.1c

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  97 in total

1.  Reliability of myocardial salvage assessment by cardiac magnetic resonance imaging in acute reperfused myocardial infarction.

Authors:  Steffen Desch; Hubertus Engelhardt; Josefine Meissner; Ingo Eitel; Mahdi Sareban; Georg Fuernau; Suzanne de Waha; Matthias Grothoff; Matthias Gutberlet; Gerhard Schuler; Holger Thiele
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

Review 2.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

3.  Measuring myocardium at risk in acute myocardial infarction--a continuing challenge.

Authors:  Todd D Miller; Raymond J Gibbons
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

4.  Segmentation of non-viable myocardium in delayed enhancement magnetic resonance images.

Authors:  Arunark Kolipaka; George P Chatzimavroudis; Richard D White; Thomas P O'Donnell; Randolph M Setser
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

Review 5.  Cardiovascular MRI for detection of myocardial viability and ischaemia.

Authors:  H Mahrholdt; I Klem; U Sechtem
Journal:  Heart       Date:  2007-01       Impact factor: 5.994

Review 6.  Characterization of myocardial viability using MR and CT imaging.

Authors:  Gabriele A Krombach; Thoralf Niendorf; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

Review 7.  Nephrogenic systemic fibrosis: a concise review for cardiologists.

Authors:  Benjamin Y C Cheong; Raja Muthupillai
Journal:  Tex Heart Inst J       Date:  2010

Review 8.  Cardiovascular magnetic resonance for the clinical cardiologist.

Authors:  Eric Larose; Josep Rodés-Cabau; Robert Delarochelliere; Gerald Barbeau; Bernard Noel; Olivier Bertrand
Journal:  Can J Cardiol       Date:  2007-10       Impact factor: 5.223

9.  Quantitation of infarct size in patients with chronic coronary artery disease using rest-redistribution Tl-201 myocardial perfusion SPECT: correlation with contrast-enhanced cardiac magnetic resonance.

Authors:  David S Fieno; Louise E J Thomson; Piotr Slomka; Aiden Abidov; John D Friedman; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

10.  Cardiac magnetic resonance imaging: long term reproducibility of the late enhancement signal in patients with chronic coronary artery disease.

Authors:  H Bülow; C Klein; I Kuehn; R Hollweck; S G Nekolla; K Schreiber; F Haas; J Böhm; B Schnackenburg; R Lange; M Schwaiger
Journal:  Heart       Date:  2005-09       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.