Literature DB >> 12403595

Dopamine transport into a single cell in a picoliter vial.

Kevin P Troyer1, R Mark Wightman.   

Abstract

The analysis of chemical events in small volumes requires careful manipulation of samples and sensitive detection methods. Here, we describe the measurement of the neurotransmitter dopamine in a picoliter vial with electrochemical techniques. The vials were fabricated from fused-silica capillaries that provided a transparent container suitable for the observation and manipulation of a biological cell, sample solutions, and electrodes. Evaporation of the sample was prevented with a mineral oil layer, allowing for experiments lasting for several minutes. The small volume of these vials (100-200 pL) allows rapid mixing of all of the solution reagents. Similarly, the small volume allows exhaustive electrolysis of the vial contents with a 3-microm radius, disk-shaped carbon fiber microelectrode within 60 s. Fast-scan cyclic voltammetry at carbon fiber microelectrodes was used to monitor the concentration of analyte in the vial without depleting its contents. The concentration of dopamine introduced by pneumatic injection remained stable when sampled by cyclic voltammetry, and no evidence for adsorption to the walls was observed. However, when the vial contained a single HEK-293 cell transfected to express the dopamine transporter, the dopamine concentration decreased with time at a rate consistent with the uptake kinetics mediated by the transporter located on the cell membrane.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12403595     DOI: 10.1021/ac0203903

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Hybrid CMOS-Graphene Sensor Array for Subsecond Dopamine Detection.

Authors:  Bayan Nasri; Ting Wu; Abdullah Alharbi; Kae-Dyi You; Mayank Gupta; Sunit P Sebastian; Roozbeh Kiani; Davood Shahrjerdi
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-12       Impact factor: 3.833

2.  Microelectrophoresis platform for fast serial analysis of single cells.

Authors:  Dechen Jiang; Christopher E Sims; Nancy L Allbritton
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

3.  Microchip electrophoresis with chemiluminescence detection for assaying ascorbic acid and amino acids in single cells.

Authors:  Shulin Zhao; Yong Huang; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2009-08-11       Impact factor: 4.759

4.  Integrated microfluidic system with chemiluminescence detection for single cell analysis after intracellular labeling.

Authors:  Shulin Zhao; Xiangtang Li; Yi-Ming Liu
Journal:  Anal Chem       Date:  2009-05-15       Impact factor: 6.986

5.  In Situ Electrochemical Monitoring of Caged Compound Photochemistry: An Internal Actinometer for Substrate Release.

Authors:  Romana Jarosova; Sam V Kaplan; Thomas M Field; Richard S Givens; Sanjeewa N Senadheera; Michael A Johnson
Journal:  Anal Chem       Date:  2021-01-25       Impact factor: 6.986

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.