Literature DB >> 12401619

The auditory steady-state response is not a suitable monitor of anesthesia.

S Pockett1, S M Tan.   

Abstract

UNLABELLED: Previous studies show that the human 40-Hz auditory steady-state response (ASSR) disappears on induction of general anesthesia, suggesting that it may be a good candidate for a monitor of anesthesia. In this study, we aimed to learn whether all normal alert adults display ASSRs with adequate signal-to-noise ratio. Clicks were presented at a series of frequencies between 35 and 70 Hz and electroencephalographic records taken at the vertex were Fourier transformed. ASSRs were observable as sharp peaks in the electroencephalograph spectrum at the frequency of the clicks. Initial results showed that a discernible ASSR could not be obtained from about half the subjects studied at any click frequency used. Further investigation revealed that in subjects whose ASSR was undetectable in the alert state, induction of a drowsy mental state resulted in appearance of an observable ASSR. This was attributable to an increase in signal in the drowsy state, not to a decrease in noise. We conclude that, because a significant proportion of subjects do not display easily recordable ASSRs when alert, it is not practical to use disappearance of the ASSR as a routine test for adequacy of anesthesia. IMPLICATIONS: Auditory steady-state responses (ASSRs) are brain waves evoked by auditory stimuli. Because they reportedly disappear under general anesthesia, they have been suggested as potential indicators of anesthetic depth. However, in this study, we show that about half our normal adult subjects did not produce measurable ASSRs when awake. This suggests that ASSRs are not good candidates for use in monitoring anesthetic depth during surgery.

Entities:  

Mesh:

Year:  2002        PMID: 12401619     DOI: 10.1097/00000539-200211000-00041

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

1.  The amplitude and phase precision of 40 Hz auditory steady-state response depend on the level of arousal.

Authors:  Inga Griskova; Morten Morup; Josef Parnas; Osvaldas Ruksenas; Sidse M Arnfred
Journal:  Exp Brain Res       Date:  2007-09-09       Impact factor: 1.972

2.  Cortical Responses to Vowel Sequences in Awake and Anesthetized States: A Human Intracranial Electrophysiology Study.

Authors:  Kirill V Nourski; Mitchell Steinschneider; Ariane E Rhone; Bryan M Krause; Rashmi N Mueller; Hiroto Kawasaki; Matthew I Banks
Journal:  Cereb Cortex       Date:  2021-10-22       Impact factor: 4.861

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.