Literature DB >> 12399713

[Utilization of a porous alumina ceramic spacer in tibial valgus open-wedge osteotomy: fifty cases at 16 months mean follow-up].

J C Bové1.   

Abstract

PURPOSE OF THE STUDY: The aim of this work was to study the behavior of an inert porous alumina ceramic spacer used with a plate fixation for open-wedge tibial valgus osteotomy in patients with osteoarthritis of the knee and genu varum.
MATERIAL AND METHODS: The population included 50 patients who underwent surgery between October 1994 and December 2000. There were 31 women and 19 men, mean age 55 years at surgery (26 right knees and 24 left knees). Patients were reviewed at 3 weeks, 6 weeks, 3 months, 6 months, and one year, then every 2 years. Clinical and radiological data were available for all patients.
RESULTS: Mean follow-up was 16 months. Two patients were lost to follow-up at 5 and 6 months. The results of the open-wedge tibial osteotomy were in agreement with the usual outcome reported in the literature concerning pain relief, functional recovery, joint motion, angle correction, and good preservation of the clinical and radiological result. Three fracture lines were observed on the lateral tibial plateau but did not affect final outcome or angle correction. There was however one case with loss of correction due to fracture of the screws. Radiographically, at 6 months, there were 9 thin lucent lines around the spacer (24%) which did not affect final outcome. Bone healing was achieved at 3 months on the average in all cases except 2 (4%) where healing was achieved at 8 and 13 months. DISCUSSION: The porous alumine spacer is a reliable biocompatible and mechanically stable element helpful for achieving bone healing. Integration into bone tissue was radiographically satisfactory. There were no specific complications related to use of the spacer.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12399713

Source DB:  PubMed          Journal:  Rev Chir Orthop Reparatrice Appar Mot        ISSN: 0035-1040


  3 in total

1.  Outcome of opening wedge high tibial osteotomy augmented with a Biosorb® wedge and fixed with a plate and screws in 124 patients with a mean of ten years follow-up.

Authors:  Dominique Saragaglia; Marc Blaysat; Dominic Inman; Numa Mercier
Journal:  Int Orthop       Date:  2010-07-29       Impact factor: 3.075

2.  Early weight bearing versus delayed weight bearing in medial opening wedge high tibial osteotomy: a randomized controlled trial.

Authors:  Joris Radboud Lansdaal; Tanguy Mouton; Daniel Charles Wascher; Guillaume Demey; Sebastien Lustig; Philippe Neyret; Elvire Servien
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-07-01       Impact factor: 4.342

3.  [Tibial valgization osteotomy by medial opening-wedge filled with cement for femorotibial 38 varus-valgus gonarthrosis].

Authors:  Amine Belmoubarik; Mohamed Amine Mahraoui; Merouane Abouchane; Yassir El Andaloussi; Ahmed Reda Haddoun; Mohamed Nechad
Journal:  Pan Afr Med J       Date:  2015-03-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.