Literature DB >> 1239747

New technique of measurement of effective capacity changes of total vascular bed.

H Suga, Y Numao, J Iriuchijima.   

Abstract

A simple device was developed which can accurately measure effective changes in total vascular capacity as viewed from the site of the heart. The device consists of a funnel and a suction bottle. It is connected via a single large-bore cannula to the right atrium of an open-chest animal without opening the closed loop of the circulation. It serves to clamp the steady-state level of mean central venous pressure precisely at any desired value and to measure the volume of any displacement of blood out of or into the total vascular bed caused by changes in total vascular capacity. The device was tested in mock and animal experiments and proved to function accurately, except during a short transient phase of less than 1 min following an intervention on the total vascular capacity. Errors in clamp pressure in the steady state, which are theoretically zero, were found to be less than 0.2 mm Hg, and were practically insignificant. Errors in the volume measurement were less than 5 ml.

Mesh:

Year:  1975        PMID: 1239747     DOI: 10.1007/bf00587347

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  9 in total

Review 1.  VEINS AND VENOUS TONE.

Authors:  B FOLKOW; S MELLANDER
Journal:  Am Heart J       Date:  1964-09       Impact factor: 4.749

2.  Reflex control of the systemic venous bed. Effects on venous tone of vasoactive drugs, and of baroreceptor and chemoreceptor stimulation.

Authors:  E BRAUNWALD; J ROSS; R KAHLER; T E GAFFNEY; A GOLDBLATT; D T MASON
Journal:  Circ Res       Date:  1963-05       Impact factor: 17.367

3.  Comparative studies on the adrenergic neuro-hormonal control of resistance and capacitance blood vessels in the cat.

Authors:  S MELLANDER
Journal:  Acta Physiol Scand Suppl       Date:  1960

4.  Active and passive release of blood from canine spleen and small intestine.

Authors:  D E Donald; L L Aarhus
Journal:  Am J Physiol       Date:  1974-11

5.  A systems approach to baroreceptor reflex control of the circulation.

Authors:  K Sagawa; M Kumada; A Shoukas
Journal:  Aust J Exp Biol Med Sci       Date:  1973-02

6.  Control of total systemic vascular capacity by the carotid sinus baroreceptor reflex.

Authors:  A A Shoukas; K Sagawa
Journal:  Circ Res       Date:  1973-07       Impact factor: 17.367

7.  Mean circulatory pressure in carotid sinus reflex.

Authors:  M Kumada; O Okai; A Gunji
Journal:  Jpn J Physiol       Date:  1971-12

8.  Total systemic vascular compliance measured as incremental volume-pressure ratio.

Authors:  A A Shoukas; K Sagawa
Journal:  Circ Res       Date:  1971-02       Impact factor: 17.367

9.  Role of the veins in the carotid sinus reflex.

Authors:  N L Browse; D E Donald; J T Shepherd
Journal:  Am J Physiol       Date:  1966-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.