Literature DB >> 12396416

Miniaturized nebulization catheters: a new approach for delivery of defined aerosol doses to the rat lung.

Ann Tronde1, George Baran, Stefan Eirefelt, Hans Lennernäs, Ursula Hultkvist Bengtsson.   

Abstract

A nebulization catheter technique (AeroProbe) was adapted and evaluated as a new approach for pulmonary delivery of defined aerosol doses to the rat lung. The lung distribution profile was evaluated by dosing Evans blue and Nile blue dye, respectively, to isolated and perfused rat lungs (IPL) and to the lungs of anesthetized and tracheal-intubated rats. The intratracheal aerosol dosing was synchronized with the inspiration of the lungs. Immediately after dosing, the lungs were dissected into upper- and lower trachea, bronchi, and parenchyma. The dye was then extracted from the tissue samples to determine the regional distribution and the recovery of the aerosol dose in the lungs. The droplet-size distribution and the weight of the delivered aerosol dose were analyzed with laser diffraction and gravimetric analysis respectively. The recovery of the delivered dose was high, 99 +/- 12 and 105 +/- 1%, respectively, in the in vivo administrations and IPL-experiments. The lung distribution profile after aerosol dosing to anesthetized rats was mainly tracheobronchial. Only 12 +/- 4% of the dose was recovered in the lung parenchyma. However, after aerosol dosing to the IPL, 38 +/- 11% of the dose was distributed to the lung parenchyma. At the settings used, the nebulization catheter aerosolized 1-2 microL of liquid per puff using 1-1.5 mL of air. The droplet-size distribution of the generated aerosols was broad (2-8% <3 microm; 10% <4-7 microm; 50% <10-15 microm; and 90% <20-40 microm). The nebulization catheter technique provides a complement to existing methodology for pulmonary drug delivery in small animals. With this new technique, defined aerosol doses can be delivered into the lungs of rats with no need for aerosol dosimetry.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12396416     DOI: 10.1089/089426802760292627

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  4 in total

1.  Aerosol Delivery of siRNA to the Lungs. Part 1: Rationale for Gene Delivery Systems.

Authors:  Susanne R Youngren-Ortiz; Nishant S Gandhi; Laura España-Serrano; Mahavir B Chougule
Journal:  Kona       Date:  2015-09-30       Impact factor: 2.897

2.  Monitoring the initial pulmonary absorption of two different beclomethasone dipropionate aerosols employing a human lung reperfusion model.

Authors:  Matthias Freiwald; Anagnostis Valotis; Andreas Kirschbaum; Monika McClellan; Thomas Mürdter; Peter Fritz; Godehard Friedel; Michael Thomas; Petra Högger
Journal:  Respir Res       Date:  2005-02-24

Review 3.  Toxicological assessment of inhaled nanoparticles: role of in vivo, ex vivo, in vitro, and in silico studies.

Authors:  Eleonore Fröhlich; Sharareh Salar-Behzadi
Journal:  Int J Mol Sci       Date:  2014-03-18       Impact factor: 5.923

Review 4.  Modifying and Integrating in vitro and ex vivo Respiratory Models for Inhalation Drug Screening.

Authors:  Aylin Cidem; Peta Bradbury; Daniela Traini; Hui Xin Ong
Journal:  Front Bioeng Biotechnol       Date:  2020-10-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.