Literature DB >> 12395361

Accurate evaluation of QT interval in conscious rhesus monkeys (Macaca mulatta) by use of Holter ECG.

Masatoshi Hassimoto1, Takuma Harada, Nobuhiko Kaga, Hiroyuki Murano, Masaomi Obata.   

Abstract

The aim of this study was to determine the best method to evaluate the QT interval with respect to the heart rate in rhesus monkeys. Rhesus monkeys (Macaca mulatta) are widely used in cardiovascular research, but the characteristics of QT-RR formulas as regards rhesus monkeys has not been sufficiently related. We analyzed the physiological QT-RR relation for practical evaluation of the QT interval in conscious rhesus monkeys by use of 24-h Holter ECG monitoring. As the QT interval varies with dependency on the RR interval, 14 QT regression functions were evaluated by use of about 50 pairs of QT-RR points per animal in 5 male rhesus monkeys. The accuracy of fit with the measured data was assessed according to the minimum Akaike information criterion. Among one-parameter linear regression functions, QT = a x (RR)(1/2), where "a" is the regression coefficient, gave the best fit, which was almost comparable to that of all multi-parameter regression functions. Our results also suggest that the QTc formula derived from the square root regression function is the most practical for evaluation of QT intervals in rhesus monkeys. In conclusion, concerning the heart rate of rhesus monkeys, we propose the modification of Bazett's formula (QTc = QT x (500)(1/2)/(RR)(1/2), where the dimension of RR and QT interval is milliseconds). We believe the information herein is quite useful for cardiovascular studies on rhesus monkeys.

Entities:  

Mesh:

Year:  2002        PMID: 12395361     DOI: 10.1054/jelc.2002.35846

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  4 in total

1.  Standard electrocardiographic data of young Japanese monkeys (Macaca fusucata).

Authors:  Arao Yamaoka; Hiroshi Koie; Tsuneo Sato; Kiichi Kanayama; Masato Taira
Journal:  J Am Assoc Lab Anim Sci       Date:  2013-07       Impact factor: 1.232

2.  Issues in QT interval measurement.

Authors:  Pallavi Lanjewar; Vaishali Pathak; Yash Lokhandwala
Journal:  Indian Pacing Electrophysiol J       Date:  2004-10-01

3.  Establishment of a new formula for QT interval correction using a large colony of cynomolgus monkeys.

Authors:  Shunya Nakayama; Hiroshi Koie; Miyoko Kato-Tateishi; Chungyu Pai; Yasuyo Ito-Fujishiro; Kiichi Kanayama; Tadashi Sankai; Yasuhiro Yasutomi; Naohide Ageyama
Journal:  Exp Anim       Date:  2019-07-12

4.  Automated video-based heart rate tracking for the anesthetized and behaving monkey.

Authors:  Mathilda Froesel; Quentin Goudard; Marc Hauser; Maëva Gacoin; Suliann Ben Hamed
Journal:  Sci Rep       Date:  2020-10-21       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.