Literature DB >> 12393779

Effects of prolonged head-down tilt on internal jugular vein cross-sectional area.

S J Schreiber1, U K W Lambert, F Doepp, J M Valdueza.   

Abstract

BACKGROUND: Head-down tilt is often used to assist cannulation of the internal jugular vein (IJV). However, the optimal duration of tilt before cannulation is not well defined.
METHODS: Fifteen healthy volunteers were studied by B-mode duplex sonography to assess changes in cross-sectional area (CSA) of the right IJV during 10 degrees head-down tilt.
RESULTS: Median CSA in the supine position was 102 mm(2) [range 16-266, mean (SD) 113 (69)]. CSA increased to 139 mm(2) [23-388, 158 (93)] immediately after tilting (P<0.0001, repeated measures ANOVA). No significant further change was noted in the next 20 min. CSA returned to baseline level after return to the supine position.
CONCLUSION: The 10 degrees head-down tilt manoeuvre in healthy volunteers causes an immediate, significant increase in CSA in the right IJV. A longer tilt did not cause further increase in jugular CSA.

Entities:  

Mesh:

Year:  2002        PMID: 12393779

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  9 in total

1.  Comparison of the effect of the Trendelenburg and passive leg raising positions on internal jugular vein size in critically ill patients.

Authors:  Funda Gok; Gamze Sarkilar; Alper Kilicaslan; Alper Yosunkaya; Sema Tuncer Uzun
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  Relationship between Trendelenburg tilt and internal jugular vein diameter.

Authors:  S Clenaghan; R E McLaughlin; C Martyn; S McGovern; J Bowra
Journal:  Emerg Med J       Date:  2005-12       Impact factor: 2.740

3.  Doppler-guided cannulation of internal jugular vein, subclavian vein and innominate (brachiocephalic) vein--a case-control comparison in patients with reduced and normal intracranial compliance.

Authors:  Wolfram Schummer; Claudia Schummer; Wolf-Dirk Niesen; Hendrik Gerstenberg
Journal:  Intensive Care Med       Date:  2003-07-24       Impact factor: 17.440

4.  Human cerebral venous outflow pathway depends on posture and central venous pressure.

Authors:  J Gisolf; J J van Lieshout; K van Heusden; F Pott; W J Stok; J M Karemaker
Journal:  J Physiol       Date:  2004-07-29       Impact factor: 5.182

5.  Effect of Trendelenburg position on right and left internal jugular vein cross-sectional area.

Authors:  Jeong Gil Lee; Hee Bin Park; Hye Young Shin; Ju Deok Kim; Soo Bong Yu; Doo Sik Kim; Sie Jeong Ryu; Gyeong Han Kim
Journal:  Korean J Anesthesiol       Date:  2014-11-26

6.  The dynamics of changing internal jugular veins diameter based on increasing head elevation angle.

Authors:  Aleksandr L Urakov; Anton A Kasatkin; Anna R Nigmatullina
Journal:  Indian J Crit Care Med       Date:  2015-10

7.  Ultrasonographic assessment of internal jugular vein diameter and its relationship with the carotid artery at the apex, middle, and base of the triangle formed by two heads of sternocleidomastoid muscle: A pilot study in healthy volunteers.

Authors:  Sohan L Solanki; Jeson R Doctor; Savi J Kapila; Anuja Jain; Malini Joshi; Vijaya P Patil
Journal:  Saudi J Anaesth       Date:  2018 Oct-Dec

8.  Sex-dependent jugular vein optical attenuation and distension during head-down tilt and lower body negative pressure.

Authors:  Courtney A Patterson; Robert Amelard; Essi Saarikoski; Hannah Heigold; Richard L Hughson; Andrew D Robertson
Journal:  Physiol Rep       Date:  2022-02

9.  Effects of incrementally increasing tidal volume on the cross-sectional area of the right internal jugular vein.

Authors:  Youn Yi Jo; Hong Soon Kim; Mi Geum Lee; Dong Young Kim; Hae Keum Kil
Journal:  Korean J Anesthesiol       Date:  2013-10-24
  9 in total