Literature DB >> 12390812

[Biomechanical study of double-plate fixation for comminuted fractures of the distal femur].

Ang-Ru Lin1, Dao-Hai Gao, Ba-Sheng Hu, Gao-Hong Ren.   

Abstract

OBJECTIVE: To explore the new treatment approach for comminuted fractures of the distal femur.
METHODS: Supra- and intercondylar comminuted fractures were induced in the femurs of 20 fresh adult cadavers, 10 of which received fixation with lateral steel plates and medial polyethylenes plates while the rest with single plate in the lateral only. Biomechanical tests of bending, torsion and compression were performed.
RESULTS: Biomechanical test demonstrated that double-plate fixation provided better resistance to compression (P<0.05) as well as bending and torsion (P<0.01) than single-plate fixation did.
CONCLUSION: Double-plate fixation is effective and may have potential clinical value in treating comminuted fractures of the distal femur.

Entities:  

Mesh:

Year:  2002        PMID: 12390812

Source DB:  PubMed          Journal:  Di Yi Jun Yi Da Xue Xue Bao        ISSN: 1000-2588


  1 in total

1.  Medial Open-wedge Osteotomy with Double-plate Fixation for Varus Malunion of the Distal Femur.

Authors:  Qi-Fang He; Han-Xu Wang; Hui Sun; Yu Zhan; Bin-Bin Zhang; Xue-Tao Xie; Cong-Feng Luo
Journal:  Orthop Surg       Date:  2019-02-05       Impact factor: 2.071