Literature DB >> 12389020

In vivo interaction of endotoxin and recombinant bactericidal/permeability-increasing protein (rBPI23): hemodynamic effects in a human endotoxemia model.

Wilbert T Jellema1, D Peter Veerman, Robbert J De Winter, Karel H Wesseling, Sander J H Van Deventer, C Erik Hack, Johannes J van Lieshout.   

Abstract

The cardiovascular derangement that results from the administration of endotoxin in healthy subjects is qualitatively similar to what is observed in patients in septic shock. The biological response to endotoxin is attributed in part to cytokine release. In experimental endotoxemia, recombinant bactericidal/permeability increasing protein (rBPI(23)) has shown a protective effect by binding endotoxin with the subsequent inhibition of the endotoxin-induced cytokine release and of neutrophil activation. In a controlled, blinded crossover study the early cardiovascular effects of rBPI(23) were investigated in an experimental endotoxemia model in humans. The beat-to-beat changes in arterial pressure and cardiac output following infusion of endotoxin (40 EU/kg body weight) and rBPI(23) (1 mg/kg) or placebo (human serum albumin, 0.2 mg/kg) were studied for 2 hours in 8 healthy male adults. Endotoxin or rBPI(23) alone did not induce significant cardiovascular changes. Endotoxin following rBPI(23) infusion elicited a fall in total peripheral resistance with its nadir after 4 minutes to 40% (range 16-53; P <.001) of control level. Mean arterial pressure showed little change, and the fall in total peripheral resistance was associated with a reflex increase in heart rate and cardiac output (32%; range 43-106). Changes in cardiovascular variables in the subsequent 2 hours were not significant. In vitro activation of the contact system by, respectively, rBPI(23), LPS, and LPS-rBPI(23) complexes was assessed. Following incubation with rBPI(23), LPS, and LPS-rBPI(23) complexes, complex levels were generated at levels comparable to those observed in the buffer control. The rapid vasodilatation by endotoxin administered concomitantly with rBPI(23) is not mediated by complement or contact system activation. The early vasodilatation is compensated by an increase in cardiac output, which therefore does not result in arterial hypotension. The monitoring of continuous cardiac output allows for the detection of rapid effects on systemic flow and conductance that go unnoticed in a recording of arterial pressure.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12389020     DOI: 10.1067/mlc.2002.127170

Source DB:  PubMed          Journal:  J Lab Clin Med        ISSN: 0022-2143


  3 in total

Review 1.  The bactericidal/permeability-increasing protein (BPI) in infection and inflammatory disease.

Authors:  Hendrik Schultz; Jerrold P Weiss
Journal:  Clin Chim Acta       Date:  2007-07-13       Impact factor: 3.786

2.  Sepsis in standard care: patients' characteristics, effectiveness of antimicrobial therapy and patient outcome--a cohort study.

Authors:  Franz Ratzinger; Katharina Eichbichler; Michael Schuardt; Irene Tsirkinidou; Dieter Mitteregger; Helmuth Haslacher; Thomas Perkmann; Klaus G Schmetterer; Georg Doffner; Heinz Burgmann
Journal:  Infection       Date:  2015-04-04       Impact factor: 3.553

3.  Systemic endotoxin levels in chronic indolent periodontal infections.

Authors:  J L Ebersole; J Stevens; M J Steffen; D Dawson Iii; M J Novak
Journal:  J Periodontal Res       Date:  2010-02       Impact factor: 4.419

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.