Literature DB >> 12388031

Ultrasound biomicroscopy of the Artisan phakic intraocular lens in hyperopic eyes.

Mihai Pop1, Yves Payette, Magdi Mansour.   

Abstract

PURPOSE: To study in situ the intraocular position of the Artisan iris-claw intraocular lens (IOL) (model 203) (Ophtec) in phakic hyperopic eyes using ultrasound biomicroscopy (UBM).
METHODS: Echograms of the anterior chamber were taken preoperatively and 24 to 317 days postoperatively in 4 eyes implanted with the Artisan IOL (power +4.0 to +6.0 diopters). The preoperative anterior chamber depth (ACD) and the postoperative distance between the IOL and the corneal endothelium (endothelium-optic distance) and between the IOL and the lens were measured. The echograms were assessed for the effect of the IOL on iris tissue.
RESULTS: The preoperative ACD ranged from 3.10 to 3.56 mm and the postoperative endothelium-optic distance, from 2.03 to 2.54 mm. The distance between the lens and the posterior surface of the IOL ranged from 0.35 to 0.79 mm. Several UBM echograms showed indentation of iris tissue by the IOL haptics and optic edge, although no pigmentary dispersion was noted.
CONCLUSIONS: Adequate space was maintained between the Artisan hyperopic IOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris, which could lead to pigment erosion, was observed. Preoperative gonioscopy and maintenance of normal intraocular pressure postoperatively suggest the indentation was secondary to inadequate lens vaulting relative to the high natural arch of the iris in hyperopic eyes. Shortening the haptics or increasing the lens vault might resolve this problem.

Entities:  

Mesh:

Year:  2002        PMID: 12388031     DOI: 10.1016/s0886-3350(02)01325-1

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Ultrasonography of the Anterior Segment.

Authors:  Martin Heur; Bennie H Jeng
Journal:  Ultrasound Clin       Date:  2008-04-01

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

4.  Explaining The Current Role Of High Frequency Ultrasound In Ophthalmic Diagnosis (Ophthalmic Ultrasound).

Authors:  D Jackson Coleman; Ronald H Silverman; Mark J Rondeau; Harriet O Lloyd; Suzanne Daly
Journal:  Expert Rev Ophthalmol       Date:  2006-10-01

5.  Tilt and decentration of posterior and anterior iris-claw intraocular lenses: a pilot study using anterior segment optical coherence tomography.

Authors:  Giacomo Calzetti; Carlo Bellucci; Salvatore Antonio Tedesco; Maurizio Rossi; Stefano Gandolfi; Paolo Mora
Journal:  BMC Ophthalmol       Date:  2022-05-23       Impact factor: 2.086

Review 6.  The Medical Devices Special Access Program in Canada: A Scoping Study.

Authors:  Roland K Maier; Devidas Menon; Tania Stafinski
Journal:  Healthc Policy       Date:  2018-02
  6 in total