Literature DB >> 12386727

Neonate aortic stenosis: importance of myocardial perfusion in prognosis.

Marco Aurélio Santos1, Vitor Manuel Pereira Azevedo.   

Abstract

OBJECTIVE: To analyze our experience with percutaneous aortic balloon valvuloplasty in newborn infants with aortic stenosis, emphasizing the extraordinary importance of myocardial perfusion.
METHODS: Over a 10-year-period, 21 neonates underwent percutaneous aortic balloon valvuloplasty. Age ranged from 2 to 27 days, weight ranged from 2.2 to 4.1 kg and 19 were males. All patients presented with congestive heart failure that could not be treated clinically. The onset of symptoms in the first week of life occurred in 9 patients considered as having critical aortic stenosis. Severe aortic stenosis occurred in 12 patients with the onset of symptoms in the second week of life.
RESULTS: Mortality reached 100% in the patients with critical aortic stenosis. The procedure was considered effective in the 12 patients with severe aortic stenosis. Vascular complications included the loss of pulse in 12 patients and rupture of the femoral artery in 2 patients. Cardiac complications included acute aortic regurgitation in 2 patients and myocardial perforation in one. In an 8.2+/-1.3-year follow-up, 5 of the 12 patients died (2 patients due to septicemia and 3 patients due to congestive heart failure). Five of the other 7 patients underwent a new procedure and 2 required surgery.
CONCLUSION: Percutaneous aortic valvuloplasty in neonates is not an effective procedure in the 1st week of life, because at this age the common presentation is cardiogenic shock. It is possible that, in those patients with critical aortic stenosis, dilation of the aortic valve during fetal life may change the prognosis of its clinical outcome.

Entities:  

Mesh:

Year:  2002        PMID: 12386727     DOI: 10.1590/s0066-782x2002001200005

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  2 in total

1.  Ascending aortic approach for balloon aortic valvuloplasty with concomitant bilateral pulmonary artery banding in a very low-birth-weight neonate with critical aortic stenosis and poor left ventricular function.

Authors:  Mitsutoshi Kimura; Yasushi Misaki; Hitoshi Kato; Yukihiro Kaneko
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

2.  Balloon Valvuloplasty of Aortic Valve Stenosis in Childhood: Midterm Results in a Children's Hospital, Mansoura University, Egypt.

Authors:  Hala Al Marshafawy; Gehan Attia Al Sawah; Mona Hafez; Mohammed Matter; Adel El Gamal; Abdel Gawad Sheishaa; Magdy Abu El Kair
Journal:  Clin Med Insights Cardiol       Date:  2012-02-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.