Literature DB >> 12385417

Reduced frequency of blood donors with false-positive HIV-1 and -2 antibody EIA reactivity after elution of low-affinity nonspecific natural antibodies.

Marlene Bouillon1, Eric Aubin, Chantal Roberge, Renée Bazin, Réal Lemieux.   

Abstract

BACKGROUND: The detection by EIA of antibodies (Abs) specific to HIV antigens in the serum of blood donors is important for transfusion safety. A small but significant number of donor sera (0.1-0.3%) yield false-positive results in EIA, and these donors must be permanently deferred from the blood donor list, causing operational and public relations problems. STUDY DESIGN AND METHODS: False-positive EIA reactions could be caused by the binding of low-affinity natural polyreactive Abs, which could be eluted by treatment with a chaotropic agent such as thiocyanate (SCN). The effect of the SCN elution on EIA specificity was studied using tetanus toxoid and HIV Abs.
RESULTS: SCN elution preferentially reduced the binding of nonspecific Abs. Testing of 235 seronegative samples in HIV-1 and -2 EIA showed that SCN elution reduced the mean and dispersion of OD values obtained. In addition, SCN elution abolished the false-positive reactivity in HIV-1 and -2 EIA of 69 percent (299/435) of the repeatedly reactive specimens tested without impact on the reactivity of HIV-seropositive specimens.
CONCLUSION: The SCN elution step increased the specificity of HIV-1 and -2 EIA and could facilitate the re-entry of previously deferred donors.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12385417     DOI: 10.1046/j.1537-2995.2002.00164.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Determination of tetanus antibodies by a double-antigen enzyme-linked immunosorbent assay in individuals of various age groups.

Authors:  K Caglar; R Karakus; C Aybay
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2005-08       Impact factor: 3.267

2.  A retrospective analysis of false-positive infectious screening results in blood donors.

Authors:  Michelle T Vo; Roberta Bruhn; Zhanna Kaidarova; Brian S Custer; Edward L Murphy; Evan M Bloch
Journal:  Transfusion       Date:  2015-10-28       Impact factor: 3.157

3.  Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

Authors:  Leslie Shanks; M Ruby Siddiqui; Almaz Abebe; Erwan Piriou; Neil Pearce; Cono Ariti; Johnson Masiga; Libsework Muluneh; Joseph Wazome; Koert Ritmeijer; Derryck Klarkowski
Journal:  Virol J       Date:  2015-05-14       Impact factor: 4.099

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.