Literature DB >> 12384317

Polyanhydride implant for antibiotic delivery--from the bench to the clinic.

Luk Chiu Li1, John Deng, Dennis Stephens.   

Abstract

A polyanhydride implant (Septacin) containing gentamicin sulfate was developed for sustained local delivery of the drug to the site of infection in the treatment of osteomyelitis. Laboratory-scale injection molding equipment was utilized to fabricate the implant for in vitro characterization. Molding conditions were optimized to produce implants with a skin-core structure which was found to be critical in preventing the initial cracking of the implant during in vitro drug release test in water. A manufacturing process consisting of twin-screw extrusion, pelletizing, and injection molding was developed. Polymer-drug pellets were characterized with respect to copolymer molecular weight and drug content uniformity. The implants were terminally sterilized by gamma-radiation which was found to cause increase in copolymer molecular weight as a result of polymer chain extension. The stability of Septacin was evaluated as a function of storage temperature and time. A marked decline in copolymer molecular weight occurred in samples stored above freezing temperatures and significantly slower drug-release profiles were also exhibited by these samples. In vivo drug release from Septacin in rats showed that the gentamicin plasma levels were extremely low, indicating the low systemic exposure to gentamicin. Furthermore, Septacin samples have demonstrated efficacy in the rat skin-abscess and horse-joint infection models. Results from a human in vivo study also showed high local drug concentrations at implantation sites while systemic exposure to the drug was minimal.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12384317     DOI: 10.1016/s0169-409x(02)00053-4

Source DB:  PubMed          Journal:  Adv Drug Deliv Rev        ISSN: 0169-409X            Impact factor:   15.470


  17 in total

Review 1.  Bone tissue engineering therapeutics: controlled drug delivery in three-dimensional scaffolds.

Authors:  Viviana Mouriño; Aldo R Boccaccini
Journal:  J R Soc Interface       Date:  2009-10-28       Impact factor: 4.118

Review 2.  Nanostructured platforms for the sustained and local delivery of antibiotics in the treatment of osteomyelitis.

Authors:  Vuk Uskokovic
Journal:  Crit Rev Ther Drug Carrier Syst       Date:  2015       Impact factor: 4.889

Review 3.  Hot-Melt Extrusion: a Roadmap for Product Development.

Authors:  Marta F Simões; Rui M A Pinto; Sérgio Simões
Journal:  AAPS PharmSciTech       Date:  2021-06-17       Impact factor: 3.246

Review 4.  Nanoparticle-based local antimicrobial drug delivery.

Authors:  Weiwei Gao; Yijie Chen; Yue Zhang; Qiangzhe Zhang; Liangfang Zhang
Journal:  Adv Drug Deliv Rev       Date:  2017-09-20       Impact factor: 15.470

5.  Pentaerythritol-based lipid A bolsters the antitumor efficacy of a polyanhydride particle-based cancer vaccine.

Authors:  Emad I Wafa; Sean M Geary; Kathleen A Ross; Jonathan T Goodman; Balaji Narasimhan; Aliasger K Salem
Journal:  Nanomedicine       Date:  2019-07-15       Impact factor: 5.307

6.  Characterization and in vitro degradation of poly(octadecanoic anhydride).

Authors:  An-Jie Dong; Jin-Wei Zhang; Kai Jiang; Lian-Dong Deng
Journal:  J Mater Sci Mater Med       Date:  2007-06-19       Impact factor: 3.896

7.  Treatment of osteomyelitis in rats by injection of degradable polymer releasing gentamicin.

Authors:  Yaron S Brin; Jacob Golenser; Boaz Mizrahi; Guy Maoz; Abraham J Domb; Shyamal Peddada; Shmuel Tuvia; Abraham Nyska; Meir Nyska
Journal:  J Control Release       Date:  2008-07-20       Impact factor: 9.776

8.  Single Dose of a Polyanhydride Particle-Based Vaccine Generates Potent Antigen-Specific Antitumor Immune Responses.

Authors:  Emad I Wafa; Sean M Geary; Kathleen A Ross; Jonathan T Goodman; Balaji Narasimhan; Aliasger K Salem
Journal:  J Pharmacol Exp Ther       Date:  2018-10-25       Impact factor: 4.030

9.  Novel bioerodable eluting-spacers for radiotherapy applications with in situ dose painting.

Authors:  Francis Boateng; Wilfred Ngwa
Journal:  Br J Radiol       Date:  2019-05-14       Impact factor: 3.039

10.  Effect of hydroxyapatite on the physicochemical characteristics of a gentamicin-loaded monoolein gel intended to treat chronic osteomyelitis.

Authors:  Rasmané Semdé; Réné Flore Gueu Gondi; Bavouma Charles Sombié; B Gérard Josias Yaméogo; Moustapha Ouédraogo
Journal:  J Adv Pharm Technol Res       Date:  2012-04
View more